{"product_id":"allen-bradley-1771-odc-6-point-isolated-ac-output-module","title":"Allen Bradley 1771-ODC 6-Point Isolated AC Output Module","description":"\u003cp\u003eThe Allen Bradley \u003cstrong\u003e1771-ODC\u003c\/strong\u003e is an individually isolated discrete AC output module for the PLC-5 and 1771 I\/O system. It provides six 120 VAC nominal output channels (92-138 VAC operating range) rated at 2 A per channel and 6 A per module. Designed for use in 1771 I\/O chassis, it includes per-channel fusing, front-panel status indicators, optical coupling, and surge suppression.\u003c\/p\u003e\n\u003ch3\u003eOutput Channels and Load Ratings\u003c\/h3\u003e\n\u003cp\u003eEach of the six isolated outputs switches loads within a 92-138 VAC operating range at 47-63 Hz. Continuous output current is rated up to 2 A per channel without exceeding 6 A total per module, with a surge rating up to 20 A maximum for 100 ms repeatable every 5 seconds when load current is 60 mA per output.\u003c\/p\u003e\n\u003cp\u003eBecause the channels are individually isolated, loads can operate on separate AC circuits, and the 120 VAC nominal output can directly energize contactors and relay coils without an interposing relay. Optical coupling, input\/signal filtering, and surge suppression circuitry help reduce electrical noise and protect against AC line transients.\u003c\/p\u003e\n\u003ch3\u003eFusing, Diagnostics, and Addressing\u003c\/h3\u003e\n\u003cp\u003eEach output channel is paired with an individual 5 A, 250 V 3AG normal-blow fuse (Buss AGC-5 \/ Littelfuse 312005). Twelve front-panel indicators display module status: six top red indicators show output state, and six bottom indicators report blown-fuse conditions.\u003c\/p\u003e\n\u003cp\u003eThe module draws 225 mA from the backplane and uses 8 image bits per module. It supports 1\/2-slot, 1-slot, and 2-slot addressing, and the provided specifications note BCD or Natural Binary data format.\u003c\/p\u003e\n\u003ch3\u003eChassis Mounting and Field Wiring\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1771-ODC\u003c\/strong\u003e mounts in a 1771 I\/O chassis with keying bands set between pins 4-6 and between pins 30-32. Field wiring connects via a removable wiring arm (listed as Cat. No. 1771-WD in the specification table and description, and also shown as 1771-WH in the specification list) with a terminal screw torque of 7-9 inch-pounds.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1771-ODC (Series C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePLC 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated discrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e6 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e92-138 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current Per Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Per Module\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current Rating\u003c\/td\u003e\n\u003ctd\u003e20 A max for 100 ms, repeatable every 5 s (with 60 mA load current per output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e225 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.2-13.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.1-45.2 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying\u003c\/td\u003e\n\u003ctd\u003eBetween 4 and 6; Between 30 and 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm\u003c\/td\u003e\n\u003ctd\u003e1771-WD; 1771-WH (listed in source specifications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm Screw Torque\u003c\/td\u003e\n\u003ctd\u003e7-9 inch-pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Fuse\u003c\/td\u003e\n\u003ctd\u003e5 A, 250 V 3AG normal blow (Buss AGC-5 \/ Littelfuse 312005), 1 per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eBCD or Natural Binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay (Off to On)\u003c\/td\u003e\n\u003ctd\u003e1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Delay (On to Off)\u003c\/td\u003e\n\u003ctd\u003e8.3 ms typical (also listed as 45 (+\/- 15) ms AC \/ 50 ms DC in source table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs (1.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Status\u003c\/td\u003e\n\u003ctd\u003eEarlier Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e10612598002990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many output channels does the Allen Bradley 1771-ODC have?A: It has 6 isolated AC output channels, with a maximum continuous current of 2 A per output and 6 A total per module. Note that one sentence in the source text mentions sixteen channels, which conflicts with the 6-output specification and front-panel six-output\/six-fuse indicator count.\u003c\/p\u003e\n\u003cp\u003eQ: What fuse type does the 1771-ODC use for each output? A: Each output has a built-in 5 A, 250 V 3AG normal-blow fuse (Buss AGC-5 or Littelfuse 312005). Six front-panel indicators report blown-fuse conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What wiring arm and screw torque are specified for field connections? A: The source specifications list wiring arm Cat. No. 1771-WD and also list 1771-WH, with a terminal screw torque of 7-9 inch-pounds. Confirm the exact wiring arm catalog number needed for your assembly before ordering.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67265944715379,"sku":"1771-ODC","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1771-ARC3_Cocoai_7c9e6d5b-e72f-44c6-95ac-ff1555cb1d5f.jpg?v=1795162464","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1771-odc-6-point-isolated-ac-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}