{"product_id":"allen-bradley-1792d-16bvt0d-devicenet-16-point-i-o-block","title":"Allen-Bradley 1792D-16BVT0D DeviceNet 16-Point I\/O Block","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1792D-16BVT0D\u003c\/strong\u003e is a 16-point digital I\/O block designed for DeviceNet-based industrial control systems. It supports sink\/source I\/O configurations and provides a distributed I\/O interface between field devices and a PLC or other compatible controller. This model is discontinued by the manufacturer and is identified by its complete catalog number, 1792D-16BVT0D.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16-point digital I\/O block.\u003c\/li\u003e\n\u003cli\u003eSink\/source I\/O configuration.\u003c\/li\u003e\n\u003cli\u003eDeviceNet communication interface.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O architecture for connecting field signals to a control network.\u003c\/li\u003e\n\u003cli\u003eManufacturer discontinued status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1792D-16BVT0D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet 16-Point I\/O Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e1792D-16BVT0D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSink \/ Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eDeviceNet Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1792D-16BVT0D uses DeviceNet communication to exchange I\/O data with a network-connected controller. In a distributed control architecture, the I\/O block provides a local connection point for field signals while communicating their status over the DeviceNet network.\u003c\/p\u003e\n\u003cp\u003eThis arrangement allows field I\/O to be located closer to connected equipment rather than requiring every signal to be wired directly to a central PLC rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSink \/ Source Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified sink\/source configuration identifies the supported digital I\/O wiring arrangement. Sink and source describe the current relationship between field devices and I\/O circuits, which must be considered when matching sensors, switches, and other field equipment.\u003c\/p\u003e\n\u003cp\u003eConfirm the terminal assignments and electrical requirements against the applicable wiring documentation before connecting field devices. The available product information does not specify individual channel voltage, current ratings, or terminal configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Availability and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1792D-16BVT0D is discontinued by the manufacturer. The supplied product listing specifies that the original factory warranty does not apply and that a \u003cstrong\u003eRadwell 2-year warranty\u003c\/strong\u003e is included.\u003c\/p\u003e\n\u003cp\u003ePurchasing and replacement planning should take the discontinued status into account, particularly when maintaining existing DeviceNet installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the Allen-Bradley 1792D-16BVT0D discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied product information explicitly identifies the 1792D-16BVT0D as discontinued by the manufacturer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication network does the 1792D-16BVT0D use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It uses DeviceNet for communication between the distributed I\/O block and the network-connected control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does sink\/source mean for this I\/O block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Sink\/source refers to the supported digital I\/O current-flow arrangement. Field device wiring must match the applicable electrical configuration and terminal requirements.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67226366869619,"sku":"1792D-16BVT0D","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1792D-16BVT0D_Cocoai_1_eedbfcc5-65fb-4533-99ce-9ef9d286b280.jpg?v=1794812506","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1792d-16bvt0d-devicenet-16-point-i-o-block","provider":"DcsSupplier Limited","version":"1.0","type":"link"}