{"product_id":"allen-bradley-1794-ov16p-flex-i-o-digital-sinking-output-module","title":"Allen-Bradley 1794-OV16P FLEX I\/O Digital Sinking Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e1794-OV16P\u003c\/strong\u003e is an Allen-Bradley FLEX I\/O digital DC output module featuring 16 protected sinking outputs for 24 VDC field circuits. Each channel supports up to 500 mA, with a maximum combined output current of 8.0 A per module. Its electronic protection responds to short circuits, overloads, and high-temperature conditions, making it suitable for switching DC loads through a FLEX I\/O terminal base assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1794-OV16P provides 16 current-sinking outputs. In a sinking configuration, the module switches the connected load toward the DC common reference, so field devices and the external power supply must be wired with the appropriate polarity.\u003c\/p\u003e\n\u003cp\u003eEach output has electronic protection against short-circuit, overload, and overtemperature conditions. According to the supplied description, the affected output shuts down during a fault and automatically recovers after the fault is removed. The stated recovery behavior does not include passing the fault status to the processor, so separate fault monitoring should not be assumed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module operates with a nominal on-state voltage of 24 VDC and supports an external supply range of 10-31.2 VDC. The maximum on-state current is 500 mA per channel, subject to the 8.0 A maximum module current rating. These limits must be considered together when distributing loads across the 16 output channels.\u003c\/p\u003e\n\u003cp\u003eThe maximum off-state voltage is 31.2 VDC, while off-state leakage is limited to 0.5 mA. The maximum on-state voltage drop is 0.2 VDC, which is relevant when checking the voltage available at connected field loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFLEX I\/O Installation and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1794-OV16P connects to field wiring through a compatible FLEX I\/O terminal base unit. The supplied technical information identifies \u003cstrong\u003e1794-TB3 and 1794-TB3S\u003c\/strong\u003e as compatible terminal bases. The module mounts on the terminal base, which provides the connection between field devices and the FLEX I\/O bus.\u003c\/p\u003e\n\u003cp\u003eThe description specifies that modules can be inserted or removed under power because the I\/O module does not have direct field wiring. This hot-insertion and removal capability should be applied according to the applicable FLEX I\/O system installation instructions and the operating requirements of the connected equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-OV16P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eFLEX I\/O 1794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFLEX I\/O Digital Sinking Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598179985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eSinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal On-state Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-state Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10-31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-state Voltage\u003c\/td\u003e\n\u003ctd\u003e31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Channel\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Module Output Current\u003c\/td\u003e\n\u003ctd\u003e8.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-state Leakage\u003c\/td\u003e\n\u003ctd\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-state Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-to-On Output Delay\u003c\/td\u003e\n\u003ctd\u003e0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-to-Off Output Delay\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexbus Current\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.2 W at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e14.3 BTU\/hr at 31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e10-31.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply AC Ripple\u003c\/td\u003e\n\u003ctd\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Current\u003c\/td\u003e\n\u003ctd\u003e20-65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 Yellow LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Bases\u003c\/td\u003e\n\u003ctd\u003e1794-TB3, 1794-TB3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module includes 16 yellow LED indicators, with one indicator corresponding to each output channel. These indicators provide local visual information about the output signal state, helping maintenance personnel identify channel activity during inspection and troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 1794-OV16P and a standard digital output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1794-OV16P uses protected sinking outputs with electronic protection against short circuits, overloads, and excessive temperature. Its protection function shuts down the affected output during a fault and automatically recovers after the fault condition is cleared.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which terminal bases are compatible with the 1794-OV16P?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify the Allen-Bradley 1794-TB3 and 1794-TB3S terminal base units as compatible options. The terminal base provides the field wiring and FLEX I\/O bus connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1794-OV16P be replaced while the system is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied product description specifies insertion and removal under power because the module has no direct field wiring. However, the procedure must follow the applicable FLEX I\/O installation requirements and account for the effect of removing output signals on the controlled equipment.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67305744498803,"sku":"1794-OV16P","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1794-OB32P_2_110f02d8-00c3-4a8d-897c-5aa7b31fb280.jpg?v=1795594329","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1794-ov16p-flex-i-o-digital-sinking-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}