{"product_id":"allen-bradley-2711-k6c1l1-panelview-600-standard-operator-terminal","title":"Allen-Bradley 2711-K6C1L1 PanelView 600 Standard Operator Terminal","description":"\u003cp\u003eAllen-Bradley \u003cstrong\u003e2711-K6C1L1\u003c\/strong\u003e is a PanelView 600 Standard human-machine interface (HMI) designed for operator control and real-time visualization in industrial automation environments. Powered by a 18 to 32 V DC supply, it combines a 5-inch color display with a physical keypad interface and dual communication ports for PLC networking and peripheral device connectivity.\u003c\/p\u003e\n\u003ch3\u003eDisplay Specifications and Keypad Control\u003c\/h3\u003e\n\u003cp\u003eThe terminal incorporates a 5-inch color display paired with a field-replaceable internal backlight (catalog number 2711-NL3. Operator interaction is managed via a dedicated keypad assembly that supports data entry, menu navigation, and system commands. System memory includes 240 KB of internal nonvolatile storage for application graphics, text, and operational parameters.\u003c\/p\u003e\n\u003ch3\u003eDual Communications and Network Architecture\u003c\/h3\u003e\n\u003cp\u003eEquipped with Allen-Bradley Remote I\/O (RIO) networking capabilities, the terminal transfers discrete and block data directly across 1771 Remote I\/O link architectures. It interfaces with SLC 500 controllers via a 1747-SN scanner module and ControlLogix platforms via a 1756-DHRIO communication module. A secondary RS-232 serial port is dedicated to external printer connections, enabling hardcopy reporting and alarm logging without disrupting active controller data traffic.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K6C1L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard Operator Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003ePanelView 600 Operator Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size \/ Type\u003c\/td\u003e\n\u003ctd\u003e5 in. Color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB Nonvolatile Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Communication\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Communication\u003c\/td\u003e\n\u003ctd\u003eRS-232 Serial Port (Printer Only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Backlight\u003c\/td\u003e\n\u003ctd\u003e2711-NL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003e2711-NC14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Series Support\u003c\/td\u003e\n\u003ctd\u003eSeries A, B, C, D, E, F, G, H, I, J, K, and L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.94 lbs (2.24 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What function does the RS-232 port serve on the 2711-K6C1L1 operator terminal? A: The RS-232 port on this specific model is configured strictly as a printer port for printing reports and alarm logs. Application transfer and real-time controller communications are carried out via the primary Remote I\/O (RIO) interface.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 2711-K6C1L1 connect to ControlLogix and SLC 500 control systems? A: The terminal joins the 1771 Remote I\/O network directly. It links to ControlLogix processors through a 1756-DHRIO module and connects to SLC 500 controllers through a 1747-SN scanner module, supporting both discrete I\/O and block transfer operations.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67031806378099,"sku":"2711-K6C1L1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711-B5A9L1_Cocoai_661b3b0d-3abb-4a67-8365-3ced607ec201.jpg?v=1793178164","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-2711-k6c1l1-panelview-600-standard-operator-terminal","provider":"DcsSupplier Limited","version":"1.0","type":"link"}