{"product_id":"allen-bradley-2711-tc1x-panelview-1200-operator-terminals","title":"Allen-Bradley 2711-TC1X PanelView 1200 Operator Terminals","description":"\u003cp\u003eConfigured for high-speed operator interaction in Remote I\/O (RIO) industrial networks, the \u003cstrong\u003eAllen-Bradley 2711-TC1X\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-TC1X\u003c\/strong\u003e Operator Terminal, provides direct physical execution of machine commands via an integrated touch-cell matrix.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-TC1X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e12-inch CRT Color Display (640 x 480 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eTouchscreen (120 touch cells: 10 across by 12 high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RIO), RS-232 (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90-264 VAC (47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e246 BTU\/hour maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e64 KB standard user RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView 1200 Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network Backplane and Firmware Flashing\u003c\/h3\u003e\n\u003cp\u003eThe terminal utilizes high-velocity backplane communication interfaces to process Remote I\/O (RIO) data traffic directly from connected programmable controllers. Featuring robust firmware compatibility across hardware revisions, the unit maintains deterministic data throughput without degrading the visual refresh rate of the 12-inch CRT screen. The discrete touch cell matrix ensures precise coordinate registration and rapid command execution in demanding plant floor environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the configuration and sizing of the discrete touch cells on the display overlay?\u003c\/p\u003e\n\u003cp\u003eA: The touchscreen features 120 individual touch cells organized in a 10-column by 12-row grid, where each cell is sized to accommodate two characters high by eight characters wide.\u003c\/p\u003e\n\u003cp\u003eQ: What input power supply parameters are required to operate the 2711-TC1X terminal safely?\u003c\/p\u003e\n\u003cp\u003eA: The unit accepts an AC input voltage range of 90 to 264 VAC at a frequency of 47 to 63 Hz, drawing power directly from standard industrial distribution transformers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify panel cutout dimensions for the PanelView 1200 housing prior to mounting the unit into a NEMA Type 12 indoor industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 100 mm around the rear chassis and ventilation grills to accommodate CRT thermal dissipation and convection airflow.\u003c\/li\u003e\n\u003cli\u003eConnect the main chassis ground terminal directly to the central panel earth ground bar using a low-impedance copper bonding strap.\u003c\/li\u003e\n\u003cli\u003eRoute Remote I\/O twinaxial communication cables and AC power wiring in separate wireways away from high-voltage motor drives and power transformers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":66927933554803,"sku":"2711-TC1X","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711-T6C3L1_72483b32-74f8-4be9-8372-438ecc4d8e10.png?v=1792394123","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-2711-tc1x-panelview-1200-operator-terminals","provider":"DcsSupplier Limited","version":"1.0","type":"link"}