{"product_id":"allen-bradley-700-hax2a1-4-general-purpose-relay","title":"Allen-Bradley 700-HAX2A1-4 General Purpose Relay","description":"\u003cp\u003eConfigured for direct physical\/electrical execution in Allen-Bradley control circuits and PLC switching loops, the \u003cstrong\u003eAllen-Bradley 700-HAX2A1-4\u003c\/strong\u003e (\u003cstrong\u003e700-HAX2A1-4\u003c\/strong\u003e General Purpose Relay) provides high-density signal switching and status isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e700-HAX2A1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCountry of Origin Not Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg (0.14 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 8-Pin Tube Base Tube-Style Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 VAC Coil (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003e2-Pole (DPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current Rating\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Base Type\u003c\/td\u003e\n\u003ctd\u003eTube Base Pin-Style Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eVisual On\/Off Indicator with Illuminated LED Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSocket \/ Tube Base Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and Deterministic Bus Performance\u003c\/h3\u003e\n\u003cp\u003eConfigured for interposing control loops linked to Allen-Bradley I\/O systems, the 700-HAX2A1-4 executes high-velocity coil actuation without feedback jitter across deterministic EtherNet\/IP process loops. Fast contact actuation times ensure predictable signal state transition execution, providing robust galvanic isolation between field actuary devices and PLC I\/O channels without degrading firmware flash compatibility or backplane control timings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 700-HAX2A1-4 relay be plugged into or removed from its base socket while coil power is applied?\u003c\/p\u003e\n\u003cp\u003eA: Live hot-swapping under load is strictly prohibited. Operating control voltage to the 120 VAC coil and field contacts must be completely de-energized before inserting or extracting the relay from its tube-style socket.\u003c\/p\u003e\n\u003cp\u003eQ: How is visual contact status determined during operation?\u003c\/p\u003e\n\u003cp\u003eA: The module includes a mechanical ON\/OFF flag indicator alongside an integrated LED option that illuminates when 120 VAC power is present across the coil terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all 120 VAC coil control lines and 6 A contact circuit feeds are fully de-energized and locked out before installation.\u003c\/li\u003e\n\u003cli\u003eAlign the keyway on the 8-pin tube-style base with the center orientation notch of the matching DIN-rail socket.\u003c\/li\u003e\n\u003cli\u003ePush the relay straight into the socket until the pin terminals seat fully into the receptacle contacts.\u003c\/li\u003e\n\u003cli\u003eVerify physical pin engagement and secure any socket retention clips to maintain terminal stability under vibration.\u003c\/li\u003e\n\u003cli\u003eApply 120 VAC coil voltage to test mechanical flag trip actuation and observe status LED illumination under active load.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":66814665850995,"sku":"700-HAX2A1-4","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711P-B7C4A1_1200x1200_____Cocoai_f6053fec-3585-4518-ad77-2399b4494eb1.jpg?v=1791442410","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-700-hax2a1-4-general-purpose-relay","provider":"DcsSupplier Limited","version":"1.0","type":"link"}