{"product_id":"analog-digital-terminal-board-ge-ds200tbcag1aaa","title":"Analog\/Digital Terminal Board | GE DS200TBCAG1AAA","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc DS200TBCAG1AAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical termination and interface board within the Universal Relay (UR) digital protection platform. It facilitates the physical connection between field-side instrumentation and the relay's internal processing modules. This board accepts a variety of analog and digital signals, providing the necessary isolation and signal conditioning before data reaches the CPU module. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment to ensure the highest level of Experience, Expertise, Authoritativeness, and Trustworthiness (E-E-A-T) for your critical protection infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDS200TBCAG1AAA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUR (Universal Relay) \/ TC2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Termination and I\/O Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-type Analog and Digital Field Signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunications Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 and Ethernet (via CPU Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Recommendation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePentium II 300 MHz or higher (for system interface)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 MB RAM (Minimum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField-to-Logic Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard UR Series Chassis Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWindows 95\/98\/NT\/2000\/XP Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Termination\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TBCAG1AAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplifies complex field wiring by providing organized terminal points for various input\/output elements. This layout reduces cabinet clutter and minimizes the risk of cross-wiring during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Conditioning\u003c\/strong\u003e: This board isolates incoming field signals before they enter the logic-level environment of the relay. This protection prevents high-voltage transients from damaging the CPU module or disrupting sensitive protection algorithms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Logic Interface\u003c\/strong\u003e: The board translates field data into precise logic signals that the UR firmware utilizes for programmable logic gates, timers, and latches. This ensures accurate execution of the protection elements defined in the relay's control features.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Transparency\u003c\/strong\u003e: Designed for modern automated plants, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TBCAG1AAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports the UR's ability to communicate over Local Area Networks (LAN). This allows for seamless data exchange between the terminal board, operator interfaces, and other networked UR devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DS200TBCAG1AAA support both analog and digital inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The UR platform is a hybrid digital-based device. This terminal board accepts a variety of signal types from field devices and converts them into logic signals used by the internal protection elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace this board while the relay is in service?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe do not recommend replacing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TBCAG1AAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile the system is powered. Always de-energize the relay and follow standard ESD protection protocols to prevent damage to the backplane or the new board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"AAA\" suffix indicate in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"AAA\" suffix identifies the specific hardware revision and assembly group. This version ensures full compatibility with standard UR chassis and current firmware logic algorithms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":42999122657395,"sku":"DS200TBCAG1AAA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/384..jpg?v=1774497253","url":"https:\/\/www.dcssupplier.com\/products\/analog-digital-terminal-board-ge-ds200tbcag1aaa","provider":"DcsSupplier Limited","version":"1.0","type":"link"}