{"product_id":"bently-nevada-330104-00-05-50-11-00-3300-xl-8-mm-extension-cable","title":"Bently Nevada 330104-00-05-50-11-00 3300 XL 8 mm Extension Cable","description":"\u003cp\u003eConfigured for high-precision physical gap and vibration signal transmission in 3500 and 3300 Machinery Monitoring Systems, the \u003cstrong\u003eBently Nevada 330104-00-05-50-11-00\u003c\/strong\u003e (\u003cstrong\u003e330104\u003c\/strong\u003e 3300 XL 8 mm Extension Cable) provides direct physical\/electrical execution. It connects the 3300 XL proximity probe to the Proximitor Sensor, relaying high-frequency radio frequency (RF) signals without amplitude distortion or phase shift across critical rotating machinery trains.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification \/ Dimension Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Extension Cable (Standard Cable Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length Option: 0.5 metres (20 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmor Option: FluidLok Armor (0.5 metres)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Length Option: 5.0 metres (16.4 feet) system matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Multiple Approvals (IA, ATEX, IECEx, CSA, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdapter Option: Standard \/ No Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-05-50-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e0.5 m cable length (5.0 m system length configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (Powered via Proximitor loop -24 VDC supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (standard); 75 mm (armored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial male and female connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Scaling \u0026amp; Proximity Probe System Calibration\u003c\/h3\u003e\n\u003cp\u003eThe 330104 extension cable maintains rigid electrical capacitance match across the eddy-current transduction circuit. Correct system tuning ensures the Proximitor Sensor maintains an accurate scale factor of 7.87 V\/mm (200 mV\/mil) when measuring target shaft deflection. In field commissioning, verified gap voltage validation (-10 VDC targets representing a 1.27 mm nominal center gap) relies entirely on maintaining matching cable lengths (5.0 m or 9.0 m overall system matching). Mismatched total lengths degrade linearity, leading to incorrect rotor dynamics monitoring and compromised cross-talk suppression between adjacent radial probe pairs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330104 extension cable length be trimmed or spliced in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. Splicing or shortening the cable alters the precise system capacitance required by the Proximitor sensor, causing severe signal attenuation and invalidating the 7.87 V\/mm scale factor.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the FluidLok armor option (-05)?\u003c\/p\u003e\n\u003cp\u003eA: The FluidLok armor prevents oil, synthetic lubricants, and process fluids from leaking through the cable interior along conduit paths into clean terminal housings.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping or disconnecting the extension cable allowed during active machine operation?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting the cable while the TSI rack is active disrupts the loop current (-24 VDC supply), resulting in immediate NOT OK status flags and potential false trip signals if voting logic is unmasked.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a minimum cable bend radius of 75 mm for armored sections during conduit pull steps to prevent coaxial core deformation.\u003c\/li\u003e\n\u003cli\u003eEnsure ClickLoc miniature coaxial connectors are fully seated and hand-tightened until the internal detent mechanism locks. Apply silicone self-fusing tape over connector joins if exposed to ambient oil spray.\u003c\/li\u003e\n\u003cli\u003eIsolate cable armor shield grounding to a single point at the Proximitor housing to prevent ground loops from corrupting dynamic vibration signals.\u003c\/li\u003e\n\u003cli\u003eEnsure proper thread engagement (5 NPT threads minimum for explosion-proof conduit fittings) when passing cable assemblies through pressure boundary penetrations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45373473456243,"sku":"330104-00-05-50-11-00","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/26_f7b9572b-4ab9-4e37-bcbd-1db26f5051f0.jpg?v=1787119780","url":"https:\/\/www.dcssupplier.com\/products\/bently-nevada-330104-00-05-50-11-00-3300-xl-8-mm-extension-cable","provider":"DcsSupplier Limited","version":"1.0","type":"link"}