{"product_id":"ci860-abb-800xa-ff-hse-communication-interface-original-stock","title":"CI860 ABB 800xA FF HSE Communication Interface Original Stock","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI860 (3BSE032444R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-performance communication gateway between the AC 800M controller and Foundation Fieldbus HSE (High Speed Ethernet) networks. This module enables the System 800xA to integrate complex field instruments, providing high-speed data throughput and advanced diagnostics at the control level. We supply the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCI860K01 kit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esolution, including the communication interface and necessary baseplate components for immediate industrial deployment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI860 \/ CI860K01 (Kit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE032444R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFoundation Fieldbus HSE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 800M Controller Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet (RJ45)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Internal via baseplate)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp. 160 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI860 utilizes 100 Mbit\/s Ethernet technology to manage massive data volumes from Foundation Fieldbus H1 segments via HSE linking devices. This prevents bottlenecks in data-heavy process environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module architecture allows for redundant configurations. If the primary interface fails, the backup unit assumes control instantaneously, ensuring zero process interruption for mission-critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis interface facilitates \"plug-and-produce\" capabilities for FF devices. It passes advanced instrument diagnostics directly to the 0800xA Asset Optimization tools, allowing maintenance teams to identify sensor drift or valve wear before failure occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Hardware Lifecycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI860 mounts directly onto the TP830 baseplate. This modular design streamlines installation in cramped control cabinets and allows for \"hot-replace\" functionality, where you replace the module without powering down the entire controller rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB constructs the CI860 with high-grade industrial housing that rejects electromagnetic interference, ensuring stable communication even when situated near high-frequency drives or heavy switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between CI860 and the CI860K01 kit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI860 refers to the individual communication module, whereas the CI860K01 designation represents a complete kit. The kit typically includes the CI860 module and the necessary mounting accessories or baseplate components required for a standard installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support redundancy within the AC 800M rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can install two CI860 modules in a redundant pair. The Control Builder software automatically manages the synchronization between the two units to provide high-availability communication for Foundation Fieldbus HSE networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older CI860 module while the system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI860 supports hot-swap functionality when used with a compatible MTU (Module Termination Unit). However, engineers must follow specific safety and synchronization procedures in the Control Builder environment to ensure the redundant switchover occurs correctly without dropping network packets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit 100% original ABB stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that every CI860 3BSE032444R1 we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e. Each unit arrives in its original factory packaging with intact serial numbers for full traceability.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42974856216691,"sku":"CI860 CI860K01 3BSE032444R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/448.1_7dc4221a-f1d7-4695-82ce-6031ee58a3cc.jpg?v=1776044580","url":"https:\/\/www.dcssupplier.com\/products\/ci860-abb-800xa-ff-hse-communication-interface-original-stock","provider":"DcsSupplier Limited","version":"1.0","type":"link"}