{"product_id":"communication-adapter-modules-allen-bradley-1785-ka3","title":"Communication Adapter Modules | Allen Bradley 1785-KA3","description":"\u003cp\u003eThe Allen Bradley \u003cstrong\u003e1785-KA3\u003c\/strong\u003e is a PLC-2 Family Communication Adapter Module designed to connect compatible PLC-2 family processors to a Data Highway Plus (DH+) network through a 1771 I\/O chassis. It supports network communication and process message transfer, with configurable baud rate, write options, and node address switches. The module requires 1.2 A of backplane current at 5 VDC and does not require a separate external power supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Function and Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1785-KA3 provides a communication interface between PLC-2 family controllers and the Data Highway Plus network. It is installed in a 1771 I\/O chassis and uses a DH+ processor cable and network drop-line for communication connections. A separate interface connection supports the Allen Bradley 1784 Industrial Terminal family.\u003c\/p\u003e\n\u003cp\u003eThree switch assemblies configure the module's network operation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDH+ baud rate switches:\u003c\/strong\u003e Set the communication baud rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWrite options switches:\u003c\/strong\u003e Configure the module's write options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNode address switches:\u003c\/strong\u003e Set the module's network node address.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese settings determine how the adapter communicates with other network nodes. The module supports process message operations and provides one diagnostic\/status LED per channel for status indication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Chassis Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module occupies a slot in a 1771 I\/O chassis, excluding the furthest-left slot, according to the supplied product description. It draws its operating power from the chassis backplane, requiring 1.2 A at 5 VDC, with no additional external power supply specified.\u003c\/p\u003e\n\u003cp\u003eThe backplane keying arrangement uses connecting bands between pins 4 and 6, and pins 22 and 24, of the top connector. The specified wiring arm is \u003cstrong\u003e1771-WN\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1785-KA3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC-2 Family Communication Adapter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Location\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O chassis, any I\/O slot except the furthest-left slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller Family\u003c\/td\u003e\n\u003ctd\u003ePLC-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eData Highway Plus (DH+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Terminal Interface\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley 1784-T50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e1.2 A at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Operation\u003c\/td\u003e\n\u003ctd\u003eProcess message handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Switches\u003c\/td\u003e\n\u003ctd\u003eDH+ baud rate, write options, node address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eDiagnostic\/status LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying (Top Connector)\u003c\/td\u003e\n\u003ctd\u003eBetween pins 4-6 and 22-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm\u003c\/td\u003e\n\u003ctd\u003e1771-WN (listed in supplied specifications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg (1.88 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DH+ baud rate, write options, and node address switches provide the hardware configuration needed to establish the adapter's network identity and communication settings. The node address identifies the adapter on the DH+ network, while the baud rate setting must be consistent with the network configuration.\u003c\/p\u003e\n\u003cp\u003eThe adapter acts as the communication interface for a PLC-2 controller rather than as an independent PLC processor. Its role is to make PLC-2 data accessible through the DH+ communication network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower and Environmental Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1785-KA3 receives its operating power directly from the 1771 I\/O chassis backplane. The specified 1.2 A at 5 VDC must be included in the chassis power supply capacity calculation, alongside the current requirements of other installed modules.\u003c\/p\u003e\n\u003cp\u003eThe specified operating temperature is 0 to 60 deg C, with storage permitted from -40 to 85 deg C. The relative humidity rating is 5% to 95% without condensation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which PLC processor family is compatible with the 1785-KA3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1785-KA3 is designed for PLC-2 family programmable controllers. It provides their connection to a Data Highway Plus network through a 1771 I\/O chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1785-KA3 require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. It receives 5 VDC power from the 1771 chassis backplane and requires 1.2 A of backplane current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked before replacing an existing 1785-KA3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the PLC-2 processor compatibility, 1771 chassis slot availability, backplane current capacity, DH+ network settings, and required processor and terminal cables. Also check the module's node address and switch configuration before commissioning.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67226065764467,"sku":"1785-KA3","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1771-SIM4_Cocoai_0ac8f362-4e41-416e-975b-7b38337966ea.jpg?v=1794809954","url":"https:\/\/www.dcssupplier.com\/products\/communication-adapter-modules-allen-bradley-1785-ka3","provider":"DcsSupplier Limited","version":"1.0","type":"link"}