{"product_id":"communications-modules-ge-fanuc-ic693cmm302d","title":"Communications Modules | GE Fanuc IC693CMM302D","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CMM302D\u003c\/strong\u003e is an Enhanced Genius Communications Module (GCM+) designed for GE Series 90-30 programmable logic controller (PLC) systems. Occupying a single slot, it connects the host CPU to a Genius serial bus, enabling high-speed peer-to-peer and master-slave communications across up to 31 external Genius devices per module. The module facilitates automated broadcast of 128 bytes of transmitted and 128 bytes of received Global Data without requiring custom communication ladder logic.\u003c\/p\u003e\n\u003ch3\u003eGlobal Data Exchange and Supported Registers\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CMM302D\u003c\/strong\u003e automatically maps Global Data to internal CPU memory tables during every PLC sweep cycle. It directly interfaces with Discrete Inputs (%I), Discrete Outputs (%Q), Analog Inputs (%AI), Analog Outputs (%AQ), Register Memory (%R), and Global Registers (%G). In addition to cyclic data exchange, industrial computers or personal computers can utilize the network connection for real-time monitoring and diagnostic data retrieval.\u003c\/p\u003e\n\u003ch3\u003eArchitecture, Rack Slotting, and Coexistence Rules\u003c\/h3\u003e\n\u003cp\u003eUp to two \u003cstrong\u003eGE Fanuc IC693CMM302D\u003c\/strong\u003e modules can be installed within a single Series 90-30 system, expanding network communication capacity up to 62 remote devices across two independent Genius buses. The card fits into CPU, expansion, or remote baseplates in any standard slot except slot 1 (the designated CPU slot). However, GCM+ modules cannot coexist in the same PLC system with standard (non-enhanced) GCM modules.\u003c\/p\u003e\n\u003ch3\u003eDiagnostics and System Indicators\u003c\/h3\u003e\n\u003cp\u003eFront-panel LED status indicators provide immediate visual diagnostics: a \u003cstrong\u003eMODULE OK\u003c\/strong\u003e LED confirms internal hardware integrity, while a \u003cstrong\u003eCOMM\u003c\/strong\u003e LED indicates active transmission on the Genius network. Advanced software-based status bits and fault logging enable remote network diagnostics and troubleshooting through connected controllers or a Genius Hand-Held Monitor (HHM).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CMM302D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced Genius Communications Module (GCM+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003eGE Series 90-30 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Device Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 31 devices per module (62 per PLC max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per PLC\u003c\/td\u003e\n\u003ctd\u003e2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Data Length\u003c\/td\u003e\n\u003ctd\u003e128 Bytes Transmit \/ 128 Bytes Receive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported PLC Memory Types\u003c\/td\u003e\n\u003ctd\u003e%G, %I, %Q, %AI, %AQ, %R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 300 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Width\u003c\/td\u003e\n\u003ctd\u003e1 Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Compatibility\u003c\/td\u003e\n\u003ctd\u003eCPU, Expansion, and Remote Baseplates (Excludes Slot 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs\u003c\/td\u003e\n\u003ctd\u003eMODULE OK, COMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C (-13 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock Limits\u003c\/td\u003e\n\u003ctd\u003e1 G @ 10-200 Hz \/ 5 G (10 ms duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lbs (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693CMM302D module be used alongside an older standard IC693CMM301 GCM module in the same Series 90-30 rack? A: No. Enhanced Genius Communications Modules (GCM+) such as the \u003cstrong\u003eGE Fanuc IC693CMM302D\u003c\/strong\u003e cannot be installed in a PLC system that contains standard (non-plus) GCM modules. All Genius communication modules in a single controller must be of the same module type.\u003c\/p\u003e\n\u003cp\u003eQ: Which rack slots can house the IC693CMM302D module? A: The \u003cstrong\u003eGE Fanuc IC693CMM302D\u003c\/strong\u003e can be installed in any available I\/O slot on CPU baseplates, expansion baseplates, or remote baseplates, except slot 1, which is reserved strictly for the CPU module.\u003c\/p\u003e\n\u003cp\u003eQ: How much Global Data can a single IC693CMM302D module transmit and receive per scan? A: Each \u003cstrong\u003eGE Fanuc IC693CMM302D\u003c\/strong\u003e module handles up to 128 bytes of transmitted Global Data and 128 bytes of received Global Data per PLC sweep cycle.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":67107501604979,"sku":"IC693CMM302D","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693ALG442B2_Cocoai_930a3572-b196-4fdd-a8c5-6e4efc949a3e.jpg?v=1793786972","url":"https:\/\/www.dcssupplier.com\/products\/communications-modules-ge-fanuc-ic693cmm302d","provider":"DcsSupplier Limited","version":"1.0","type":"link"}