{"product_id":"dc-output-modules-general-electric-ic693mdl740g","title":"DC Output Modules | General Electric IC693MDL740G","description":"\u003cp\u003eThe General Electric \u003cstrong\u003eIC693MDL740G\u003c\/strong\u003e is a 16-point positive-logic DC output module designed to provide discrete control signals to external field devices. It uses a sourcing output configuration with two groups of eight points, supporting 12\/24 VDC operation. The G revision module has a maximum output current of 0.5 A per point and a maximum current of 2 A per common.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Configuration and Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL740G provides 16 discrete DC output points arranged in two groups of eight. Its positive-logic sourcing configuration supplies current from the module output to connected loads when an output is activated.\u003c\/p\u003e\n\u003cp\u003eThe 12\/24 VDC nominal operating voltage supports compatible DC field devices. The maximum output current is 0.5 A per point, while each common is limited to 2 A. These limits must both be observed when distributing loads across the two output groups.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics and Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports an output voltage range of 12-24 VDC, with a tolerance of +20% and -15%. The maximum output voltage drop is 1 V, which should be considered when checking the voltage available at connected field devices.\u003c\/p\u003e\n\u003cp\u003eField-to-logic isolation is rated at 1500 V, while group-to-group isolation is rated at 500 V. The specified inrush current is 4.78 A for 10 ms. This transient rating should be considered when evaluating the startup characteristics of connected loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL740G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e16-Point DC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Groups\u003c\/td\u003e\n\u003ctd\u003e2 groups of 8 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic \/ Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12-24 VDC (+20%, -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Output Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Common\u003c\/td\u003e\n\u003ctd\u003e2 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4.78 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Drop\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the output configuration of the IC693MDL740G?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is a 16-point positive-logic DC sourcing output module. The outputs are divided into two groups, each containing eight points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the current limitations of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each output point supports a maximum current of 0.5 A, and each common is limited to 2 A. Both limits must be considered when allocating connected loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What isolation ratings does the IC693MDL740G provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module specifies 1500 V field-to-logic isolation and 500 V group-to-group isolation. These ratings describe different isolation boundaries and should not be treated as interchangeable.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":67257904038003,"sku":"IC693MDL740G","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL940D2_Cocoai_2282c0a2-0c15-4850-8559-32b3507bf2e9.jpg?v=1795077848","url":"https:\/\/www.dcssupplier.com\/products\/dc-output-modules-general-electric-ic693mdl740g","provider":"DcsSupplier Limited","version":"1.0","type":"link"}