{"product_id":"discrete-output-module-schneider-tsxdsz08t5-8-channel","title":"Discrete Output Module | Schneider TSXDSZ08T5 8-Channel","description":"\u003cp\u003eThe \u003cstrong\u003eTSXDEZ32D2\u003c\/strong\u003e is a 32-channel discrete input module for the Schneider Electric Modicon TSX Micro Automation Platform. It accepts 24 VDC field signals with positive or negative input logic and supports PNP and NPN 2-wire or 3-wire proximity sensors. Its screw terminal connections provide the interface between field devices and the PLC input system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Configuration and Signal Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXDEZ32D2 provides 32 discrete input channels for monitoring external switching signals. It operates with a nominal 24 VDC input supply and supports both positive and negative logic, allowing it to interface with different field signal arrangements.\u003c\/p\u003e\n\u003cp\u003eThe module is compatible with 2-wire and 3-wire PNP\/NPN proximity sensors. Its input characteristics allow PLC logic to recognize sensor states according to defined voltage and current thresholds.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Thresholds and Response Time\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified operating voltage range is 19-30 VDC. The input state is determined by the following guaranteed thresholds:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eState 1 is guaranteed at an input voltage of 11 V or higher and an input current of 6 mA or higher.\u003c\/li\u003e\n\u003cli\u003eState 0 is guaranteed below 5 V and at an input current of 2 mA or lower.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe response time from state 0 to state 1 is specified as 0.1-7.5 ms. This parameter is relevant when evaluating input detection timing in PLC sequences, particularly where sensor switching frequency and control response requirements must be considered.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Standards\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module has a specified isolation voltage of 1500 VAC for 1 second and meets IEC 1131-2 Type 2 requirements. These characteristics are relevant when checking electrical interface requirements and the applicable input classification within a PLC installation.\u003c\/p\u003e\n\u003cp\u003eThe stated current consumption is 254 mA with positive logic. This value should be considered when checking the electrical loading of the PLC power supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEZ32D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon TSX Micro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Operating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive or negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed State 1 Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed State 0 Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaranteed State 0 Current\u003c\/td\u003e\n\u003ctd\u003e= 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e3.4 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (State 0 to State 1)\u003c\/td\u003e\n\u003ctd\u003e0.1-7.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire PNP\/NPN proximity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Type\u003c\/td\u003e\n\u003ctd\u003eLeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e254 mA (positive logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC, 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 1131-2 Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Unit\u003c\/td\u003e\n\u003ctd\u003ePCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits per Package\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Height\u003c\/td\u003e\n\u003ctd\u003e5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Width\u003c\/td\u003e\n\u003ctd\u003e18.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Length\u003c\/td\u003e\n\u003ctd\u003e26.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Weight\u003c\/td\u003e\n\u003ctd\u003e540 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input channels does the TSXDEZ32D2 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The TSXDEZ32D2 provides 32 discrete input channels with screw terminal connections for field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which proximity sensors are compatible with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified input compatibility includes 2-wire and 3-wire PNP and NPN proximity sensors. The sensor output voltage and current must meet the module's input thresholds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TSXDEZ32D2 operate with both positive and negative input logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The supplied specifications identify support for positive and negative input logic. The actual input wiring and PLC configuration should match the selected logic arrangement.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67236288823411,"sku":"TSXDSZ08T5","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TSXDSZ08T5_45c097fc-2403-4c67-9286-6dcfeea9eba2.png?v=1794902166","url":"https:\/\/www.dcssupplier.com\/products\/discrete-output-module-schneider-tsxdsz08t5-8-channel","provider":"DcsSupplier Limited","version":"1.0","type":"link"}