{"product_id":"ds200tccbg1bed-ge-analog-board-brand-new-original","title":"DS200TCCBG1BED GE Analog Board Brand New Original","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc DS200TCCBG1BED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary TC2000 Analog I\/O interface for the Universal Relay (UR) digital protection platform. This board facilitates the high-speed conversion and isolation of field signals into logic-level data for the UR CPU. It handles a complex array of analog inputs and outputs, allowing the relay to execute protection algorithms, programmable logic, and timing functions with sub-millisecond precision. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment, ensuring your critical protection and control systems maintain peak authoritativeness and uptime.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDS200TCCBG1BED\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC2000 \/ UR (Universal Relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input\/Output Signal Processing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePentium class or higher (for interface\/programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 and high-speed Ethernet support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 MB RAM (Minimum for software interface)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated galvanic isolation for field-to-logic paths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Elements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLogic gates, timers, and latches support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWindows 95 through Windows XP\/2000 compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-layer PCB with high-density component population\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Signal Isolation\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCBG1BED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates advanced isolation circuits that shield the UR CPU from field-side voltage spikes and electrical noise. This protects the sensitive Pentium-class processing modules and prevents false tripping in high-EMI environments like substations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Logic Execution\u003c\/strong\u003e: This board converts raw field data into clean logic signals used by the relay’s firmware algorithms. It ensures that programmable logic gates and timers receive accurate data for real-time protection and control features.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Network Integration\u003c\/strong\u003e: Designed for LAN-based architectures, the board supports rapid communication between the operator interface and other UR devices. This enables synchronized control across multiple digital relays in a distributed protection network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Firmware Synergy\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC2000 Analog Board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eworks in direct tandem with the UR CPU firmware. This synergy allows for the complex implementation of latching features and protection elements that standard PLC I\/O cards cannot handle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200TCCBG1BED be used in a GE Mark V or Mark VI turbine control system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCCBG1BED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebelongs specifically to the UR (Universal Relay) and TC2000 family. While GE uses similar part numbering across series, always verify the firmware and backplane compatibility of your specific relay chassis before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board require manual calibration for analog inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDigital Universal Relays typically perform self-calibration and offset adjustment upon startup. However, we recommend performing a secondary loop check using a calibrated signal generator during commissioning to verify field-to-logic accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"BED\" suffix indicate in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"BED\" suffix denotes the specific hardware revision and component assembly version. This revision ensures compatibility with newer UR CPU modules and incorporates updated protective coating for industrial longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":42999132061811,"sku":"DS200TCCBG1BED","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/383..jpg?v=1774496922","url":"https:\/\/www.dcssupplier.com\/products\/ds200tccbg1bed-ge-analog-board-brand-new-original","provider":"DcsSupplier Limited","version":"1.0","type":"link"}