{"product_id":"emerson-396571-02-6-input-module","title":"Emerson 396571-02-6 Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson 396571-02-6\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e396571-02-6\u003c\/strong\u003e Input Module, operates as a dedicated hardware component for isolated signal acquisition within ControlWave Micro system platforms. This module provides direct physical execution of data conversion from 24 VDC field sensors to the backplane communication bus, utilizing an integrated LED daughterboard to provide immediate visual status of channel activity and loop health.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e396571\u003c\/strong\u003e: Base model designator for the isolated digital input module series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Functional variant defining the input voltage threshold and filtering characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\u003c\/strong\u003e: Revision and connector configuration index, indicating support for the 24 VDC local termination scheme.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e396571-02-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (0.26 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact system-specific rack-mount geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC local supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInput Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input\u003c\/td\u003e\n\u003ctd\u003eIsolated 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eIntegrated LED daughterboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Metrics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e The module features galvanic isolation between the field input circuitry and the system backplane. This architecture prevents ground potential differences and electrical transients from the field sensors from propagating into the CPU backplane, ensuring that individual sensor faults do not compromise the integrity of the overall control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Compatibility:\u003c\/strong\u003e While primarily a digital input device, the electrical characteristics of the input stage are optimized to maintain the integrity of loops where digital signaling is collocated with HART loop protocol instrumentation. This prevents signal attenuation and ensures that state changes are detected with the necessary precision for reliable sequence-of-event logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module compatible with existing ControlWave Micro racks?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 396571-02-6 is designed as a direct-fit component for standard ControlWave Micro rack architectures. Ensure the backplane firmware is up to date to support the specific revision index of this module.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the LED daughterboard?\u003c\/p\u003e\n\u003cp\u003eA: The integrated daughterboard provides local physical status indication. It serves as a real-time diagnostic tool, allowing operators to verify the presence of 24 VDC at each input point without requiring external multimeters or handheld diagnostic terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Seating:\u003c\/strong\u003e Align the module carefully with the rack guide rails before applying pressure to the ejector levers. Ensure the backplane connector is fully seated; an incomplete connection often results in intermittent digital input state reporting or a \"Module Missing\" error in the CPU configuration software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e To minimize electromagnetic interference (EMI), field signal wiring must use shielded twisted-pair cabling. Terminate the cable shield at the centralized instrumentation earth bus within the cabinet. Avoid grounding the shield at the field device end to prevent the formation of ground loops that could induce false state changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Constraints:\u003c\/strong\u003e Secure all field wires into the 24 VDC local connector with sufficient terminal tension. As this module is frequently used in high-vibration environments, ensure that wires have appropriate strain relief to prevent mechanical fatigue at the termination point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45149630267507,"sku":"396571-02-6","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-03_10-57-59.png?v=1783049875","url":"https:\/\/www.dcssupplier.com\/products\/emerson-396571-02-6-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}