{"product_id":"emerson-cl6824x1-a6-12p0767x032-analog-input-output-module","title":"Emerson CL6824X1-A6 12P0767X032 Analog Input\/Output Module","description":"\u003cp\u003eConfigured for high-precision signal integration in DCS architectures, the \u003cstrong\u003eEmerson CL6824X1-A6\u003c\/strong\u003e (\u003cstrong\u003e12P0767X032\u003c\/strong\u003e) Analog Input\/Output Module provides direct physical execution of analog-to-digital and digital-to-analog conversion for process control loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCL6824X1-A6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.1 x 24.8 x 26.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003e4 AI \/ 4 AO channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol:\u003c\/strong\u003e The module supports native 4-20 mA HART loop protocol standards, allowing for the acquisition of primary process variables alongside secondary diagnostic data from smart field instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA Connectivity:\u003c\/strong\u003e Designed for seamless integration into fieldbus-enabled DCS cabinets, the module architecture allows for the mapping of analog points into digital communication segments, supporting deterministic data exchange.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e Each channel is electrically isolated to prevent the propagation of ground loops and common-mode noise between distinct field circuits, maintaining the integrity of the 16-bit measurement signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC):\u003c\/strong\u003e The module is engineered with low-thermal-signature components, preserving stable environmental conditions for adjacent precision analog and thermocouple inputs within high-density DCS racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module allow for simultaneous signal type configuration per channel?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each input and output channel is software-configurable to operate in either 4-20 mA or 0-10 V modes, enabling mixed-signal application on a single module.\u003c\/p\u003e\n\u003cp\u003eQ: How do the LED diagnostics indicate a fault state?\u003c\/p\u003e\n\u003cp\u003eA: The front-panel LED indicators reflect real-time channel activity. A steady status indicates normal operation, while non-standard flash patterns or extinguished LEDs denote a loss of signal, open loop, or channel-level diagnostic fault.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the module onto a standard industrial DIN rail. Ensure the chassis is fully seated to maintain contact with the system backplane and to provide structural stability against cabinet-induced vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the module chassis ground terminal to the system main earth bus using a low-impedance cable. This ensures the effectiveness of internal EMI shielding and voltage transient suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Employ shielded, twisted-pair cabling for all analog signal paths. Route these cables away from high-voltage AC lines and VFD output conductors to mitigate electromagnetic noise injection. Terminate shields consistently at the cabinet's designated grounding point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45163025399923,"sku":"CL6824X1-A6 12P0767X032","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-06_15-07-57_3a09301a-4849-487a-a5fa-3d599cd0ead6.png?v=1783325312","url":"https:\/\/www.dcssupplier.com\/products\/emerson-cl6824x1-a6-12p0767x032-analog-input-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}