{"product_id":"emerson-deltav-ve5009-system-power-supply","title":"Emerson DeltaV VE5009 System Power Supply","description":"\u003cp\u003eConfigured for physical and electrical power distribution within DeltaV M-series platforms, the \u003cstrong\u003eEmerson DeltaV VE5009\u003c\/strong\u003e (\u003cstrong\u003eVE5009\u003c\/strong\u003e 24\/12-VDC Enhanced System Power Supply) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE5009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV power supply footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C (-40 to 140 deg F) without de-rating, 60 to 70 deg C (140 to 158 deg F) with de-rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C (-40 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power Input\u003c\/td\u003e\n\u003ctd\u003eDC input, 2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Specifications\u003c\/td\u003e\n\u003ctd\u003e12 VDC (-4 to +5%) at 14.8 A, 24 VDC +\/- 20% at 6.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eInternally fused, non-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eOutput protected at 110% to 120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10 g 1\/2-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by operational load limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Power Stabilization\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Control\u003c\/strong\u003e: Prevents electrical loop-to-loop transients and common-mode voltages from coupling back into sensitive backplane logic processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Parallel Noise Protection\u003c\/strong\u003e: Integrates low-pass filtering on output stages to suppress switching noise, protecting HART digital communication signals from signal distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Overvoltage Protection Execution\u003c\/strong\u003e: Provides localized safety clamps on outputs to protect downstream DCS cards, initiating automatic trip actions between 110% and 120% of rated voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management Stability\u003c\/strong\u003e: Operates reliably without de-rating up to 60 deg C, automatically managing internal temperature profiles when transitioning to de-rated modes up to 70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input power configurations are supported by the VE5009?\u003c\/p\u003e\n\u003cp\u003eA: The VE5009 supports dual DC input ranges, operating at either a nominal 12 VDC (-4% to +5%) at 14.8 A or 24 VDC (+\/- 20%) at 6.1 A.\u003c\/p\u003e\n\u003cp\u003eQ: How is the input protection on the VE5009 managed if a fault occurs?\u003c\/p\u003e\n\u003cp\u003eA: The VE5009 contains non-replaceable internal fuses. If a major fault trips an internal fuse, the module must be replaced as a complete assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Can this power supply be hot-swapped while installed on a redundant power carrier?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When paired on a redundant carrier, the VE5009 supports online hot-swapping, enabling the user to replace a failed module without disrupting operational backplane power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Latching and Insertion\u003c\/strong\u003e: Place the VE5009 into its assigned slot on the local power carrier. Push back firmly until the mechanical security latch locks into position to guarantee low-resistance electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shield Continuity\u003c\/strong\u003e: Ensure the carrier frame is bonded directly to the local instrument ground busbar with a low-impedance conductor of at least 4.0 mm squared cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearances inside Enclosures\u003c\/strong\u003e: Mount the power carrier horizontally and maintain a minimum of 100 mm vertical clearance above and below the units to support natural convection cooling, especially when operating above 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45238603481203,"sku":"VE5009","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/104_4dcb64a6-3498-4d71-925f-0231bec947b4.png?v=1784099831","url":"https:\/\/www.dcssupplier.com\/products\/emerson-deltav-ve5009-system-power-supply","provider":"DcsSupplier Limited","version":"1.0","type":"link"}