{"product_id":"emerson-epro-a0760gp-accelerometer","title":"Emerson EPRO  A0760GP Accelerometer","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson EPRO A0760GP\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA0760GP\u003c\/strong\u003e Industrial Accelerometer, operates as a dedicated hardware component for high-precision vibration monitoring and seismic acceleration tracking within machinery protection systems. This stainless-steel piezoelectric sensor, weighing 0.15 lbs, provides direct physical and electrical execution by converting mechanical casing vibrations into proportional analog voltage signals for upstream turbomachinery monitoring racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA0760GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFactory Standard Global Site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 lbs (0.068 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel with welded hermetic sealing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-54 to +121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor \/ Sensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 50g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015 2-Pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eSensors \u0026amp; Switches \/ Accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Execution\u003c\/h3\u003e\n\u003cp\u003eThe A0760GP manages dynamic acceleration tracking and raw voltage waveform transmission directly across the system's distribution backplane. To resolve high-frequency rotor dynamics and transfer continuous vibration data concurrently without software loop execution lag or attenuation over long cable runs, the sensor's internal charge amplifier stage optimizes loop impedance matching across the active 18-28 VDC powered transmission line. This direct signal conversion prevents ambient electrical noise from distorting critical phase or amplitude values, directly supporting deterministic loop tracking rules and expanding physical I\/O density scaling options within central machine monitoring panels. Because the sensor captures high-consequence machinery data, the acceleration tracking registers maintain complete signal and firmware flash compatibility with upstream engineering master modules, ensuring that alarm limit profiles, fast Fourier transform (FFT) calculation scripts, and cross-talk suppression matrices align over the bus lines without causing signal transit noise or communication timeouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 100 mV\/g scale factor sensitivity affect the input scaling settings on the upstream monitoring module?\u003c\/p\u003e\n\u003cp\u003eA: The upstream monitor must be configured to map a 100 mV AC input variance to exactly 1 g ($9.81\\text{ m\/s}^2$) of acceleration. Misconfiguring this scale factor prevents accurate rotor dynamics tracking and will corrupt the peak-to-peak vibration registers.\u003c\/p\u003e\n\u003cp\u003eQ: What protection does the welded hermetic sealing provide in harsh industrial processing environments?\u003c\/p\u003e\n\u003cp\u003eA: The welded hermetic sealing completely isolates the internal piezoelectric crystal and amplifier circuit from moisture, oil mist, and chemical vapors. This prevents conductive tracking and insulation degradation inside the stainless steel case, maintaining the sensor's calibration up to its 121 deg C temperature limit.\u003c\/p\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45058361917555,"sku":"A0760GP","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-01_15-31-27.png?v=1780303186","url":"https:\/\/www.dcssupplier.com\/products\/emerson-epro-a0760gp-accelerometer","provider":"DcsSupplier Limited","version":"1.0","type":"link"}