{"product_id":"emerson-epro-con01-signal-converter","title":"Emerson EPRO CON01 Signal Converter","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson EPRO CON01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON01\u003c\/strong\u003e Signal Converter, operates as an interface hardware component for signal conditioning within industrial instrumentation loops. This module transforms raw sensor inputs into standardized industrial output formats, providing the necessary signal amplification and noise filtering for integration into PLC or DCS data acquisition networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 50 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, +\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, +\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Conditioning and Industrial Interfacing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Processing and Noise Suppression:\u003c\/strong\u003e The CON01 architecture implements active signal conditioning circuits to decouple low-level sensor noise from the primary measurement variable. By enforcing strict gain control and filtering out high-frequency electromagnetic interference, the device produces a clean output signal suitable for long-distance transmission to centralized control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing and Durability:\u003c\/strong\u003e The unit is encapsulated in a high-impact polycarbonate housing rated for IP67 ingress protection. This design prevents atmospheric moisture, dust, or particulate contamination from compromising the internal PCB logic, allowing for direct field-mount deployment near the sensing point without requiring auxiliary secondary enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON01 output be scaled to represent non-linear input values from a sensor?\u003c\/p\u003e\n\u003cp\u003eA: The CON01 is primarily a linear signal conditioner. It maintains a constant gain and offset defined by its factory calibration. While it performs excellent amplification and noise rejection for linear signals, it does not perform software-defined curve fitting or non-linear characterization. Any non-linear linearization must be handled by the receiving control system logic.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP67 protection rating maintained if the cable glands are not fully tightened?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP67 rating relies on a proper hermetic seal at the cable entry point. If the glands are loose, undersized, or improperly seated, moisture and conductive debris will ingress into the housing, which will result in signal drift and eventual failure of the internal circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Physical Positioning:\u003c\/strong\u003e Secure the housing to a vibration-dampened surface using the integrated mounting points. Ensure that the device is oriented to prevent the pooling of liquids or debris on the housing face. Install the unit away from high-current switching equipment to minimize the induction of transient noise into the input stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Procedures:\u003c\/strong\u003e Use shielded, twisted-pair cabling for all input and output signal paths. Terminate the shield at the instrumentation grounding bus only at the receiving end of the signal chain. Leaving the sensor-side shield ungrounded (floating) at the CON01 prevents the formation of ground loops that could otherwise degrade the +\/- 0.1% accuracy specification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45147364819059,"sku":"CON01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-08_15-10-09_db6363ab-beae-4af9-979b-cced3d1896b4.png?v=1782986741","url":"https:\/\/www.dcssupplier.com\/products\/emerson-epro-con01-signal-converter","provider":"DcsSupplier Limited","version":"1.0","type":"link"}