{"product_id":"emerson-epro-con021-pr6423-000-040-eddy-current-signal-converter-system","title":"Emerson EPRO CON021+PR6423\/000-040 Eddy Current Signal Converter System","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson CON021+PR6423\/000-040\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021+PR6423\/000-040\u003c\/strong\u003e Eddy Current Signal Converter System, operates as a dedicated hardware component for non-contact shaft displacement tracking and real-time vibration conversion within machinery protection networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6423\/000-040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFactory Standard Global Site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~120 grams (CON021) \/ 100 grams (PR6423\/000-040)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 mm x 50 mm x 10 mm (PR6423\/000-040 Sensor Body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 deg C (CON021) \/ -40 to 125 deg C (PR6423\/000-040)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by -21 VDC to -32 VDC input rail supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sensitivity\u003c\/td\u003e\n\u003ctd\u003e10 mV\/micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Rise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-23 VDC to -32 VDC (Standard) \/ -21 VDC to -32 VDC (Alternative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC (Standard) \/ -2 VDC to -18 VDC (Alternative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eLMgSi 0.5 F22 (CON021 Enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Connection\u003c\/td\u003e\n\u003ctd\u003eSelf-locking Lemo plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminal type (max 1.5 mm2 with wire-end sleeves)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Impedance\u003c\/td\u003e\n\u003ctd\u003eInput: 1 MOhm \/ Output: 50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 (CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Execution\u003c\/h3\u003e\n\u003cp\u003eThe CON021+PR6423\/000-040 manages high-frequency eddy-current probe scaling and continuous gap voltage validation directly across the machinery protection interface. To evaluate micro-displacement anomalies and transmit raw dynamic waveforms concurrently without signal attenuation or cross-talk distortion, the CON021 driver modules optimize analog processing sequences. The system tracks the modulated impedance of the 8 mm sensor coil as it interfaces with the target shaft, matching the 10 mV\/micron sensitivity across a wide 0 to 4 mm span. This analog layout routes low-level signals cleanly back to the central processing matrix, suppressing external high-frequency noise and stabilizing the 4-20 mA HART loop protocol parameters or variable voltage outputs. This execution preserves absolute trace integrity across backplane communication links, ensuring that loop calibration vectors download over the line paths without causing signal transit noise or communication timeouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does changing the supply voltage from the standard range to the alternative range impact the driver output scaling?\u003c\/p\u003e\n\u003cp\u003eA: Shifting the supply voltage to the alternative -21 VDC to -32 VDC range alters the corresponding output window to -2 VDC to -18 VDC instead of the standard -4 VDC to -20 VDC. The upstream DCS or PLC input module must be adjusted to match this alternative voltage scaling to prevent signal clipping at the measurement boundaries.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation prerequisites when interfacing the CON021 with a PR6425 series sensor?\u003c\/p\u003e\n\u003cp\u003eA: The standard CON021 framework cannot directly scale the PR6425 sensor loop. The PR6425 configuration requires the deployment of an extended range signal converter variant, designated as the CON021\/91x-xxx model, to accommodate different coil impedance profiles.\u003c\/p\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45058369192051,"sku":"CON021+PR6423\/000-040","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/998943ccf92fe8b8dcfa86fa4521597f_9a07c3c0-3863-4a46-88e5-4df098826351.png?v=1780303340","url":"https:\/\/www.dcssupplier.com\/products\/emerson-epro-con021-pr6423-000-040-eddy-current-signal-converter-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}