{"product_id":"emerson-epro-con021-pr6423-10r-010-current-monitoring-system","title":"Emerson EPRO CON021+PR6423\/10R-010 Current Monitoring System","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson EPRO CON021+PR6423\/10R-010\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021+PR6423\u003c\/strong\u003e monitoring system, operates as a dedicated hardware component for non-contact shaft displacement and vibration measurement within EPRO machine condition monitoring networks. This matched 8 mm probe and signal converter pair registers mechanical rotor dynamics against ferromagnetic targets, providing conditioned analog output for turbine protection logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021 + PR6423\/10R-010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~320 g (Combined system mass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eProbe: -40 to +180 deg C; Converter: -30 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSized by negative supply (-21 V to -32 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Air Gap\u003c\/td\u003e\n\u003ctd\u003e1 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic Steel (AISI 4140)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eProbe: IP67; Converter: IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTSI Monitoring and Signal Dynamics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling:\u003c\/strong\u003e The system relies on the conversion of high-frequency carrier signals into linear voltage offsets as the conductive target passes the probe tip. The PR6423 series utilizes a specific coil geometry calibrated to an 8 mm tip diameter, ensuring the 7.87 V\/mm sensitivity remains stable within the +\/- 0.1%\/deg C temperature coefficient range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation:\u003c\/strong\u003e Successful installation requires precise calibration to the 1 mm nominal air gap. Validation of the gap voltage (typically targeting -10 VDC at the converter output) ensures the system operates in the linear zone of its dynamic range. Deviation from this target gap results in non-linear signal clipping or potential saturation at the converter output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cross-Talk Suppression:\u003c\/strong\u003e When multiple probes are installed in high-density turbomachinery bearing housings, proper physical separation must be maintained to prevent signal cross-talk. The high-frequency excitation of the CON021 converter must be phase-matched if probes are mounted in close proximity to prevent beat-frequency interference in the vibration spectrum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the CON021 handle the negative voltage power rail requirement?\u003c\/p\u003e\n\u003cp\u003eA: The CON021 is designed to operate on a negative DC rail (-21 V to -32 VDC), which is standard for API 670 compliant machinery protection systems. This negative supply allows the converter to produce a negative-going voltage output relative to common, which is the industry standard for representing proximity to a shaft target in TSI applications.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 5-meter fluoropolymer cable be shortened or spliced?\u003c\/p\u003e\n\u003cp\u003eA: No. The cable is factory-calibrated as an integral component of the probe's total electrical length. Splicing or modifying the cable alters the distributed capacitance and inductance of the measurement loop, which will invalidate the sensitivity and require the entire system to be sent for factory re-calibration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Seating and Gap Setting:\u003c\/strong\u003e Thread the PR6423 probe into the bearing housing mount. Using a non-magnetic feeler gauge, confirm a 1 mm gap between the sensor face and the shaft. Once the gap is confirmed, tighten the locknuts to ensure the probe remains stationary, as thermal expansion of the turbine casing can shift the gap during startup\/shutdown sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate the transducer signal leads at the CON021 converter screw terminals (max 1.5 mm squared wire). Keep the cable shield isolated at the probe end to prevent ground loops. The shield should be grounded only at the instrumentation rack bulkhead. Ensure the wiring is routed within grounded metallic conduits, physically separated from high-voltage AC phase cables to prevent noise injection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45147362066547,"sku":"CON021+PR6423\/10R-010","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/87a2d25a21e917f5d1a82f9a1ca690b6_95b93fd3-a7d7-4e97-b6cd-4714905d8d7a.png?v=1782986664","url":"https:\/\/www.dcssupplier.com\/products\/emerson-epro-con021-pr6423-10r-010-current-monitoring-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}