{"product_id":"emerson-epro-con021-pr6424-000-100-sensor-system","title":"Emerson EPRO CON021+PR6424\/000-100 Sensor System","description":"\u003cp\u003eThe \u003cstrong\u003eEPRO CON021+PR6424\/000-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021\u003c\/strong\u003e Eddy Current Signal System, operates as a dedicated hardware component for non-contact radial and axial shaft displacement, position, eccentricity, and speed monitoring within mechanical monitoring and TSI networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6424\/000-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~120 grams (4.24 oz) converter mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eRail\/chassis-mount inline configuration profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (CON021)\u003c\/td\u003e\n\u003ctd\u003e-30 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp (PR6424)\u003c\/td\u003e\n\u003ctd\u003e-25 to +125 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz processing bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Rise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us step response rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Resistance\u003c\/td\u003e\n\u003ctd\u003e5 g shock and vibration threshold at 60 Hz at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 (CON021 Converter) \/ IP67 (PR6424 Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\/Output Path 1\u003c\/td\u003e\n\u003ctd\u003e-23 VDC to -32 VDC input for -4 VDC to -20 VDC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\/Output Path 2\u003c\/td\u003e\n\u003ctd\u003e-21 VDC to -32 VDC input for -2 VDC to -18 VDC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eLMgSi 0.5 F22 aluminum alloy construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Terminals\u003c\/td\u003e\n\u003ctd\u003eLemo self-locking transducer plug, max 1.5 mm2 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTurbine Supervisory Instrumentation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CON021+PR6424\/000-100 driver runs high-frequency sub-circuits engineered to maintain precise eddy-current probe scaling coefficients across fluid-film machine bearing casings. The system targets a wide 0.25 mm to 10 mm measurement range, using the CON021 converter block to regulate the raw RF energy delivered to the PR6424 sensor head and linearize the returning electromagnetic boundary data.\u003c\/p\u003e\n\u003cp\u003eThe system setup evaluates changing voltage steps against exact gap voltage validation (-10 VDC targets) settings during dynamic loop indexing. This 0 to 20,000 Hz processing network tracks high-speed variations in rotor dynamics, outputting analog displacement trends to capture oil film whirl, unbalance forces, structural rubs, and thrust bearing thermal migration before damage thresholds are crossed. The internal circuit traces maintain rigid cross-talk suppression metrics, allowing radial X\/Y pairs and axial position sensors to reside in the same physical plane on the machine casing without generating channel modulation errors or signal phase anomalies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical system states dictate the selection between the two distinct supply and output voltage configurations?\u003c\/p\u003e\n\u003cp\u003eA: The configuration is dependent on the downstream monitoring system framework. The -23V to -32V input supply yields a standard -4V to -20V output range optimized for traditional TSI infrastructure. The -21V to -32V input supply drives a -2V to -18V output curve designed to match specific legacy rack architectures or specialized high-impedance processing cards.\u003c\/p\u003e\n\u003cp\u003eQ: How do the different protection ratings of the CON021 and PR6424 affect their physical deployment limits?\u003c\/p\u003e\n\u003cp\u003eA: The PR6424 sensor features a sealed, corrosion-resistant IP67 metal housing optimized for harsh machine internal environments containing hot oil, moisture, and high vibration. The CON021 converter possesses an IP20 rating, meaning it has no fluid ingress protection and must be mounted inside a dry, weather-tight local terminal box or central control enclosure.\u003c\/p\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45067151245427,"sku":"CON021+PR6424\/000-100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-01_15-55-08_2b3a1925-ee76-4141-98f6-4d97ae4aed09.png?v=1780555116","url":"https:\/\/www.dcssupplier.com\/products\/emerson-epro-con021-pr6424-000-100-sensor-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}