{"product_id":"emerson-epro-con021-pr6424-000-110-eddy-current-sensor-system","title":"Emerson EPRO CON021+PR6424\/000-110 Eddy Current Sensor System","description":"\u003cp\u003eThe \u003cstrong\u003eEPRO CON021+PR6424\/000-110\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021\u003c\/strong\u003e Eddy Current Proximity System, operates as a dedicated hardware component for non-contact radial and axial shaft displacement monitoring within mechanical monitoring and TSI networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6424\/000-110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg net system mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.1 cm W x 15.9 cm H x 10.8 cm D housing profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +90 deg C limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via external machine monitoring rack loop supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e+-2.0 mm operational span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 Hz specialized low-frequency processing bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e0.25% maximum deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 359, DIN 43745 standards baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eEEx ib IIC T6\/T4 intrinsically safe classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructural Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel sleeve assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Composition\u003c\/td\u003e\n\u003ctd\u003ePTFE insulated cable jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Options\u003c\/td\u003e\n\u003ctd\u003e4 m, 5 m, 8 m, 10 m calibrated lengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTurbine Supervisory Instrumentation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CON021+PR6424\/000-110 acquisition loop utilizes specialized sub-circuits designed to maintain strict eddy-current probe scaling coefficients across fluid-film machine bearings. The sensor transmits a regulated electromagnetic field via the stainless steel sleeved head, tracking changing boundary layer impedances to sustain gap voltage validation (-10 VDC targets) benchmarks during initial zero-point mechanical positioning.\u003c\/p\u003e\n\u003cp\u003eThe internal driver configuration focuses on processing a highly specialized 0 to 10 Hz frequency range, optimizing the loop for low-frequency rotor dynamics, static shaft position, thermal growth displacement, and steady-state eccentricity detection. The system incorporates rigid cross-talk suppression barriers between adjacent channels, enabling radial X\/Y sensor pairs to be deployed in the same physical plane without inducing inductive phase errors or signal modulation across the PTFE-insulated cabling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do the cable length options (4m, 5m, 8m, 10m) impact the calibrated accuracy of the system?\u003c\/p\u003e\n\u003cp\u003eA: Eddy current measurement loops are highly sensitive to total circuit impedance, resistance, and capacitance. The CON021 converter must be paired with the exact PTFE cable length option specified during factory calibration; swapping a 4 m cable for a 10 m line without recalibrating the internal driver will distort the 0.25% linearity error profile.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation restrictions imposed by the EEx ib IIC T6\/T4 explosion protection rating?\u003c\/p\u003e\n\u003cp\u003eA: The EEx ib rating signifies that the PR6424 sensor head and field cabling are intrinsically safe for hazardous environments. However, this compliance requires the field loops to be driven through a certified intrinsic safety barrier located in the safe area cabinet, which restricts fault energy from migrating to the field terminals.\u003c\/p\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45067151310963,"sku":"CON021+PR6424\/000-110","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-04_14-37-12_6e92fe13-4990-46a3-bc7c-fcefe4c74a73.png?v=1780555107","url":"https:\/\/www.dcssupplier.com\/products\/emerson-epro-con021-pr6424-000-110-eddy-current-sensor-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}