{"product_id":"emerson-kc3010x1-ba2-analog-input","title":"Emerson KC3010X1-BA2 Analog Input","description":"\u003cp\u003eConfigured for 16-channel analog input monitoring in DeltaV S-Series automation setups, the \u003cstrong\u003eEmerson KC3010X1-BA2\u003c\/strong\u003e (\u003cstrong\u003eKC3010X1-BA2\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKC3010X1-BA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV S-Series module footprint weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eFits standard S-Series rack-mounted carrier slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA (Local Bus Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Configuration\u003c\/td\u003e\n\u003ctd\u003e4-20 mA with HART support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Architecture\u003c\/td\u003e\n\u003ctd\u003eIsolated analog current input loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 30 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock Limits\u003c\/td\u003e\n\u003ctd\u003e10g (1\/2 sinewave for 11 ms duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (2 to 13.2 Hz) \/ 0.7g (13.2 to 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3 harsh environment rating for airborne contaminants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control System Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Connectivity\u003c\/strong\u003e The module executes high-precision analog input processing while simultaneously decoding digital HART variable streams across all 16 channels. This network architecture routes secondary, tertiary, and diagnostic field instrument data points straight to the central DeltaV database without extending the execution time of the analog loop scan cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Performance\u003c\/strong\u003e Independent instrumentation channels incorporate dedicated galvanic isolation fields. This physical boundary blocks common-mode noise propagation, cross-channel interference, and field ground loops, preserving overall measurement accuracy across the analog-to-digital converter sub-components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the KC3010X1-BA2 module deliver power to the field-side loop transmitters?\u003c\/p\u003e\n\u003cp\u003eA: The module supplies a regulated 24 VDC loop excitation voltage limited to 30 mA per individual channel. This dedicated layout ensures each current loop remains completely isolated and self-contained, preventing a short circuit on one field device from disrupting neighboring input channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can the KC3010X1-BA2 module be hot-swapped while the primary DeltaV S-Series rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is engineered with sequenced electrical terminal contact pins that handle live rack extraction and insertion under power. This mechanical configuration allows for immediate hot-swap component replacement without requiring a system reboot or interrupting active field wiring terminations.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45090780938355,"sku":"KC3010X1-BA2","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-11_11-14-54_b8be2765-61c3-45a1-a0f7-6f5e03344ba1.png?v=1781147950","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kc3010x1-ba2-analog-input","provider":"DcsSupplier Limited","version":"1.0","type":"link"}