{"product_id":"emerson-kj2101x1-ba1-charm-i-o-card","title":"EMERSON KJ2101X1-BA1 CHARM I\/O Card","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson KJ2101X1-BA1\u003c\/strong\u003e, also cataloged under manufacturing part number \u003cstrong\u003eSE6501T01\u003c\/strong\u003e, serves as the primary \u003cstrong\u003eKJ2101X1-BA1\u003c\/strong\u003e CHARM I\/O Card (CIOC) utilized to execute high-density signal consolidation, network routing, and deterministic communication tasks across Emerson DeltaV control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eKJ2101X1-BA1 (Alt: SE6501T01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Automation Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family \/ Series\u003c\/td\u003e\n\u003ctd\u003eDeltaV Electronic Marshalling \/ CHARM Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCHARM I\/O Card (CIOC) \/ Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity Scope\u003c\/td\u003e\n\u003ctd\u003eHandles up to 96 individual CHARM I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNative Interface Protocols\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output, Digital Input\/Output, Pulse, HART signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDual redundant 100 Mbps Ethernet channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-bus galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C extended thermal boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Envelope\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Mounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN rail or dedicated cabinet mount infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.50 kg (1.10 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Software Baseline\u003c\/td\u003e\n\u003ctd\u003eDeltaV v11 and higher software configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance and Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, ATEX, FM, CSA, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrument Integration\u003c\/h3\u003e\n\u003cp\u003eThe CHARM I\/O Card (CIOC) functions as the primary digital core for electronic marshalling installations, interfacing a cluster of up to 96 characterization modules directly with the host controller architecture. By matching distinct hardware parameters at the individual slot level, the card processes native analog, digital, pulse, and HART field loops simultaneously without requiring external intermediate conversion barriers.\u003c\/p\u003e\n\u003cp\u003eData streaming and system configuration packets execute over redundant 100 Mbps Ethernet links running across Profinet, EtherNet\/IP, or native DeltaV deterministic networks. This topology maintains nominal backplane bus communication velocity baselines, stripping away propagation delays during high-density I\/O scaling routines. Onboard processing layers continuously track signal wellness and channel-to-channel isolation faults, forwarding real-time telemetry updates to the central DCS while ensuring complete software firmware flash compatibility and continuous connection tracking across all assigned instrumentation paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the CIOC manage power and communication line failures inside an electronic marshalling cluster?\u003c\/p\u003e\n\u003cp\u003eA: The card features full internal physical redundancy interfaces for both input power lines and Ethernet networks. If an active communication path or primary power rail fails, the internal hardware shifts to the standby lines instantly, maintaining continuous connection tracking without causing process sags.\u003c\/p\u003e\n\u003cp\u003eQ: Is a firmware flash step mandatory when replacing a CIOC in an existing DeltaV architecture?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The replacement unit must be loaded with a matching firmware baseline via the DeltaV Explorer interface to ensure firmware flash compatibility with the active v11+ software environment and to accurately restore the saved 96-channel database configuration.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45064406892659,"sku":"KJ2101X1-BA1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-03_15-26-34_17514934-1926-4815-bb89-74b399afdf68.png?v=1780473518","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kj2101x1-ba1-charm-i-o-card","provider":"DcsSupplier Limited","version":"1.0","type":"link"}