{"product_id":"emerson-kj3001x1-bj1-12p0555x152-output-module","title":"EMERSON KJ3001X1-BJ1 12P0555X152 Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eEMERSON KJ3001X1-BJ1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e12P0555X152\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for driving discrete field actuators and switching logic within Emerson DeltaV DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3001X1-BJ1 (12P0555X152)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEMERSON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 x 10.2 x 12.7 cm (1.50 x 4.02 x 5.00 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem bus powered via carrier backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eDeltaV CHARM \/ Electronic Marshalling Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms loop updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe (IS) field loop support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe EMERSON KJ3001X1-BJ1 digital output card integrates within DeltaV Electronic Marshalling infrastructure, delivering high-density channel-to-channel isolation between field switching circuits and backplane control logic. Designed for seamless integration with CHARM I\/O Cards (CIOC), the internal circuitry provides intrinsic safety barrier isolation (Ex i) directly to hazardous area field devices. Deterministic network communication allows up to four DeltaV controllers to access output state data simultaneously with 50 ms loop update rates over standard Ethernet backplane channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the integrated Intrinsically Safe (IS) design reduce cabinet space compared to traditional DCS marshalling?\u003c\/p\u003e\n\u003cp\u003eA: The module embeds intrinsic safety protection directly on the terminal carrier footprint, eliminating the need for separate external IS barriers, inter-cabinet cross-wiring, and additional rail-mounted isolation hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Can this digital output module be hot-swapped during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. DeltaV I\/O components support Removal and Insertion Under Power (RIUP), allowing field technicians to replace the module on an energized carrier without disrupting adjacent channels or taking the controller offline.\u003c\/p\u003e\n\u003cp\u003eQ: How many DeltaV controllers can simultaneously interface with signals from a single CHARM I\/O assembly?\u003c\/p\u003e\n\u003cp\u003eA: A single CHARM I\/O card can serve field signal data to up to four controllers across the Ethernet-based DeltaV control network while maintaining 50 ms update timing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCarrier Terminal Slot Insertion: Align the KJ3001X1-BJ1 module with the designated carrier terminal base and press firmly until the retaining latches fully engage the backplane bus connector.\u003c\/li\u003e\n\u003cli\u003eField Loop Isolation and Wiring: Wire digital field load devices to the terminal block points. Ensure intrinsic safety separation rules are maintained when routing field conductors to hazardous areas.\u003c\/li\u003e\n\u003cli\u003eGrounding and Shield Terminations: Terminate low-impedance functional earth ground leads directly to the carrier grounding bar to preserve electromagnetic compatibility and internal isolation barrier integrity.\u003c\/li\u003e\n\u003cli\u003eConduits and Cable Routing: Route digital output field conductors in separate grounded metal conduits or segregated cable trays away from high-voltage AC lines to prevent capacitive noise coupling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45460100382835,"sku":"KJ3001X1-BJ1 12P0555X152","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/KJ2002X1-BA1_2__Cocoai_331fb071-202e-41f4-a388-43bcc5153c61.jpg?v=1788836227","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kj3001x1-bj1-12p0555x152-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}