{"product_id":"emerson-kj3002x1-bf1-12p1732x082-deltav-rtd-input-module","title":"EMERSON KJ3002X1-BF1 12P1732X082 DeltaV RTD Input Module","description":"\u003cp\u003eConfigured for temperature sensor signal processing in DeltaV DCS architectures, the \u003cstrong\u003eEMERSON KJ3002X1-BF1\u003c\/strong\u003e (\u003cstrong\u003eKJ3002X1-BF1\u003c\/strong\u003e RTD Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Catalog\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRevision \/ Assembly\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSystem Assembly Part\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eKeying \/ Housing\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eKJ3002X1\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBF1\u003c\/strong\u003e: RTD Input Card\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e12P1732X082\u003c\/strong\u003e: Spare Assembly\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVE4003S6B1\u003c\/strong\u003e: System Part\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eClass G3\u003c\/strong\u003e: IP20 Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3002X1-BF1 (12P1732X082 \/ VE4003S6B1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEMERSON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.4 x 10.2 x 10.8 cm (1.73 x 4.02 x 4.25 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLocalBus power rating: 12 VDC at 160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e5.5 VDC at 0.6 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3 conformally coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Protection\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (5-16 Hz), 0.5 g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation (CJC) and Process Control Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe EMERSON KJ3002X1-BF1 RTD module routes multi-channel resistance temperature detector signals into the DeltaV LocalBus backplane architecture. Designed for precise thermal monitoring, the onboard hardware excitation supplies 5.5 VDC at 0.6 mA per channel while converting microvolt resistance changes into digital temperature values. Integrated channel-to-channel isolation and ISA-S71.04 Class G3 conformal coating preserve signal integrity and internal analog-to-digital converter accuracy under harsh atmospheric industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary backplane power requirements for operating this module on a DeltaV carrier?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power directly from the DeltaV LocalBus rail, requiring 12 VDC at 160 mA continuous current to energize internal signal conditioning and processing logic.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be installed in environments with corrosive airborne contaminants?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module features ISA-S71.04 Class G3 conformal coating, protecting onboard electronics against harsh atmospheric gases, airborne pollutants, and high-humidity process environments.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported when servicing this module on an active DeltaV carrier?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The card supports Removal and Insertion Under Power (RIUP), allowing field technicians to replace the module on an energized carrier without disrupting communications on adjacent I\/O slots.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCarrier Base Alignment: Align the module edge connector with the target slot on the DeltaV 2-wide or 8-wide carrier. Press the module firmly onto the backplane bus interface until the top and bottom latching tabs lock into place.\u003c\/li\u003e\n\u003cli\u003eRTD Lead Wiring and Shielding: Connect 2-wire, 3-wire, or 4-wire RTD sensor leads directly to the corresponding terminal block points. Terminate the overall cable shield at the carrier grounding bar to minimize high-frequency noise interference.\u003c\/li\u003e\n\u003cli\u003eSignal Line Separation: Route low-level RTD sensor leads in grounded, dedicated metal conduits, keeping a minimum distance of 300 mm from high-voltage AC conductors and motor power cables.\u003c\/li\u003e\n\u003cli\u003eTerminal Block Keying: Verify that the physical terminal block keying matches the KJ3002X1-BF1 hardware profile to prevent accidental installation of incorrect module types into the slot position.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45460123779187,"sku":"KJ3002X1-BF1 12P1732X082","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/KJ1501X1-BC2_1__Cocoai_2d4c02d2-9044-4e60-89cb-7a6fb7c71943.jpg?v=1788836240","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kj3002x1-bf1-12p1732x082-deltav-rtd-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}