{"product_id":"emerson-kj3201x1-ba1-di-card-24v-dry-contact","title":"Emerson KJ3201X1-BA1 DI Card 24V Dry Contact","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ3201X1-BA1 Digital Input (DI) Card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for use in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV distributed control system (DCS)\u003c\/strong\u003e. This module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V dry contact digital inputs\u003c\/strong\u003e, enabling reliable monitoring of field signals in industrial automation systems. It is engineered for dependable performance in harsh environments and meets multiple international hazardous-area certifications.\u003c\/p\u003e\n\u003ch3\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocal Bus Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 VDC at 150 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBussed Field Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC at 100 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Circuit Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC at 5 mA per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 g half-sine wave for 11 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 mm peak-to-peak from 2 to 13.2 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0.7 g from 13.2 to 150 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass G3 (ISA-S71.04-1985)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eATEX Certification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFM13ATEX0034U\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIECEx Certification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIECEx FMG 13.0015U\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExplosion Protection Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eII 3 G Ex nA [ic] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eII 3 G Ex nA [nL] IIC Gc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Key Position:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eB1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Safety Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField power must be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremoved before connecting or disconnecting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O loop assessment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis required for all energy-limited nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe unit\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emust not be inserted or removed while the system is powered\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-sparking field circuits must be de-energized\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebefore removing or inserting the module, including the fused terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erotary keying system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures proper compatibility between I\/O cards and terminal blocks after installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44442590118003,"sku":"KJ3201X1-BA1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/KJ3002X1-BG2_2.jpg?v=1773191439","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kj3201x1-ba1-di-card-24v-dry-contact","provider":"DcsSupplier Limited","version":"1.0","type":"link"}