{"product_id":"emerson-kj3222x1-bk1-analog-input","title":"Emerson KJ3222X1-BK1 Analog Input","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson KJ3222X1-BK1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ3222X1-BK1\u003c\/strong\u003e S-Series Analog Input Card, serves as the primary \u003cstrong\u003eKJ3222X1-BK1\u003c\/strong\u003e PLC Module\/Rack utilized to execute high-precision analog signal acquisition and HART telemetry routing tasks across Emerson DeltaV control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eKJ3222X1-BK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Automation Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family \/ Series\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-Series I\/O Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by Manufacturer (Legacy Spares Support Available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Category\u003c\/td\u003e\n\u003ctd\u003eHigh-Precision Analog Input Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density Scope\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e12 - 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Signal Input Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Interoperability\u003c\/td\u003e\n\u003ctd\u003eIntegrated HART digital communication supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor Type\u003c\/td\u003e\n\u003ctd\u003eCompact S-Series plug-in module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.77 kg (1.70 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C standard functional cabinet ambient limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrument Integration\u003c\/h3\u003e\n\u003cp\u003eThe 8-channel analog input card installs onto an S-Series passive I\/O carrier, connecting the DeltaV processing core directly to variable field instruments. The card features independent signal conditioning circuits for each channel, transforming incoming 4-20 mA analog currents into internal logic data variables without introducing localized propagation delays. An onboard FSK modem layer extracts secondary HART communication variables from the analog lines, mapping digital field diagnostics directly across Profinet, EtherNet\/IP, or native DeltaV deterministic networks via the master controller head. This dual-layer processing handles simultaneous process variable tracking and device health monitoring, allowing high-density I\/O scaling routines and remote firmware flash compatibility while keeping continuous connection tracking active across the plant network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the HART protocol interface operate alongside the primary 4-20 mA analog signal on this card?\u003c\/p\u003e\n\u003cp\u003eA: The card uses an internal Frequency Shift Keying (FSK) modem to overlay the high-frequency digital HART signal on top of the analog 4-20 mA current loop. Because the digital signal has an average value of zero, it does not interfere with the primary analog process variable measurement.\u003c\/p\u003e\n\u003cp\u003eQ: Can this analog input card be removed from its carrier slot while the system is under power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The S-Series I\/O infrastructure supports online module replacement (hot-swapping). The passive carrier chassis isolates data paths and steps down voltage surges during removal, preventing data corruption or loss of connection tracking on adjacent active channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Slot Mechanical Attachment:\u003c\/strong\u003e Align the rear connector shroud of the KJ3222X1-BK1 card with the assigned slot on the S-Series passive carrier. Push the module straight inward until the top and bottom latching mechanisms snap into the carrier chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Loop Cable Shielding:\u003c\/strong\u003e Route all 4-20 mA HART signal wires through dedicated, low-voltage grounded wire ways. Terminate the outer twisted-pair cable shields at the carrier grounding rail using a single-point earth ground to eliminate external high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Feed Verifications:\u003c\/strong\u003e Confirm that the 12-24 VDC field power supply lines are properly regulated and fused to support the loop current demands before energizing the module slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Path Isolation:\u003c\/strong\u003e Maintain distinct mechanical separation between the analog input signal paths and high-voltage AC cables, motor leads, or inductive switching circuits to block electromagnetic noise from injecting transients into the input filters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45064406827123,"sku":"KJ3222X1-BK1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-03_15-39-55_a42b1558-793b-4801-a973-d26b261d38fe.png?v=1780474042","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kj3222x1-bk1-analog-input","provider":"DcsSupplier Limited","version":"1.0","type":"link"}