{"product_id":"emerson-kj4010x1-bg1-12p0830x062-deltav-localbus-right-extenders","title":"EMERSON KJ4010X1-BG1 12P0830X062 DeltaV LocalBus Right Extenders","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson KJ4010X1-BG1 12P0830X062\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e12P0830X062\u003c\/strong\u003e LocalBus Right Extender, operates as a dedicated hardware component for right-side LocalBus interface connection execution within DeltaV S-series and Electronic Marshalling systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4010X1-BG1 12P0830X062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 16.5 cm x 3.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12.6 VDC at 8 A (LocalBus Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-series and Electronic Marshalling systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Orientation\u003c\/td\u003e\n\u003ctd\u003eRight-side extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Extension Length\u003c\/td\u003e\n\u003ctd\u003eCombined I\/O carrier length must not exceed 6.5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g, 1\/2-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (5 to 16 Hz), 0.5g (16 to 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe KJ4010X1-BG1 right extender preserves LocalBus signal integrity and maintains full HART data pass-through capabilities across multi-carrier layouts. Designed to pass communication logic without introducing signal degradation, the module supports downstream channel-to-channel isolation and system backplane optical isolation architectures across connected analog and digital I\/O nodes. High common-mode noise suppression limits ground potential interference across extended carrier buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum physical limitation for total carrier bus length when using this extender?\u003c\/p\u003e\n\u003cp\u003eA: The combined total I\/O carrier length across the LocalBus assembly must not exceed 6.5 meters.\u003c\/p\u003e\n\u003cp\u003eQ: How is the extender mechanically mounted to adjacent carrier rails?\u003c\/p\u003e\n\u003cp\u003eA: The module features a tool-free snap-in connection design that directly links adjacent Electronic Marshalling and S-series I\/O carriers.\u003c\/p\u003e\n\u003cp\u003eQ: What power parameters are carried across the LocalBus interface?\u003c\/p\u003e\n\u003cp\u003eA: The LocalBus bus power infrastructure supplies 12.6 VDC at up to 8 A directly through the extender architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the male and female LocalBus edge connectors on the carrier interface for debris prior to mounting.\u003c\/li\u003e\n\u003cli\u003eAlign the right extender with the right edge of the primary I\/O carrier and snap it into place without forcing the connector pins.\u003c\/li\u003e\n\u003cli\u003eEnsure the overall length of the interconnected carrier chain does not exceed the maximum allowed limit of 6.5 meters.\u003c\/li\u003e\n\u003cli\u003eGround the mounting DIN rails in accordance with standard DeltaV system cabinet earthing procedures to prevent static discharge.\u003c\/li\u003e\n\u003cli\u003eConfirm that the operating enclosure maintains ambient conditions within -40 to +70 deg C and ISA-S71.04-1985 Class G3 contaminant limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45438043914355,"sku":"KJ4010X1-BG1 12P0830X062","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/KJ4001X1-NA112P3373X012.png?v=1788416393","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kj4010x1-bg1-12p0830x062-deltav-localbus-right-extenders","provider":"DcsSupplier Limited","version":"1.0","type":"link"}