{"product_id":"emerson-kl1604x1-ba1-deltav-charm-safety-isolation-port","title":"Emerson KL1604X1-BA1 DeltaV CHARM Safety Isolation Port","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson KL1604X1-BA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKL1604X1-BA1\u003c\/strong\u003e Safety Isolation Port (Copper), operates as a dedicated hardware component for galvanic signal separation and communication routing within DeltaV Electronic Marshalling platforms. Operating across CHARM I\/O subsystem racks, this interface module manages digital bus signals while maintaining physical safety barriers in hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL1604X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV CHARM Base Slot Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5.0 VDC at 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Medium\u003c\/td\u003e\n\u003ctd\u003eCopper Interface Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Limit\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (2 to 13.2 Hz), 0.7g (13.2 to 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContaminant Level\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Airborne Contaminants Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Certifications\u003c\/td\u003e\n\u003ctd\u003eATEX II 3G Ex ec IIC Gc, IECEx, Class I Div 2, Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KL1604X1-BA1\u003c\/strong\u003e incorporates galvanic channel-to-channel isolation barriers to protect sensitive backplane electronics from potential field fault transients. Designed for integration alongside 4-20 mA HART loop protocol field channels, the module prevents ground loop propagation across CHARM terminal bases. Its Class G3 conformal coating isolates internal trace networks against airborne contaminants, preserving signal conversion accuracy across severe industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the KL1604X1-BA1 module be hot-swapped while energized in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit cannot be removed or inserted with system power energized unless the surrounding atmosphere is confirmed to be non-hazardous.\u003c\/p\u003e\n\u003cp\u003eQ: What power input supply is required to drive the KL1604X1-BA1 safety isolation port?\u003c\/p\u003e\n\u003cp\u003eA: The module operates from an internal backplane power rail supplying +5.0 VDC at 200 mA.\u003c\/p\u003e\n\u003cp\u003eQ: Does the KL1604X1-BA1 safety port require routine field calibration or adjustment?\u003c\/p\u003e\n\u003cp\u003eA: No. The module contains no user-serviceable internal components and requires no periodic calibration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that field power to the targeted CHARM carrier is de-energized or verify that the area is free of ignitable gas concentrations before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eInspect the copper pin connectors on the \u003cstrong\u003eKL1604X1-BA1\u003c\/strong\u003e base for bent contacts, dust, or physical contamination.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the designated CHARM terminal slot and press firmly until the locking tab engages fully with the baseplate.\u003c\/li\u003e\n\u003cli\u003eRefer to installation document 12P5403 (\"DeltaV Electronic Marshalling Zone 2 Installation Instructions\") for specific wiring and grounding procedures in Class I, Division 2 and Zone 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003eVerify cabinet grounding bar connections to ensure earth continuity and maintain Class G3 airborne contaminant shielding performance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45353319563379,"sku":"KL1604X1-BA1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/KL1604X1-BA1_20.png?v=1786591033","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kl1604x1-ba1-deltav-charm-safety-isolation-port","provider":"DcsSupplier Limited","version":"1.0","type":"link"}