{"product_id":"emerson-kl3101x1-ba1-deltav-electronic-charm-module","title":"EMERSON KL3101X1-BA1 DeltaV Electronic CHARM Module","description":"\u003cp\u003eConfigured for single-channel field signal conditioning and I\/O execution in DeltaV Electronic Marshalling platforms, the \u003cstrong\u003eEmerson KL3101X1-BA1\u003c\/strong\u003e (\u003cstrong\u003eKL3101X1-BA1\u003c\/strong\u003e Electronic CHARM Module) provides direct physical\/electrical execution. This characterization module mounts to terminal blocks on CHARM I\/O subsystem carriers, converting field-level signals into digital backplane communications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL3101X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg (0.14 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV CHARM Base Slot Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e32 mA at 6.3 VDC \/ 25 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Bus Power\u003c\/td\u003e\n\u003ctd\u003e6.3 VDC at 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Loop Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eElectronic CHARM Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDeltaV Electronic Marshalling (CHARM I\/O Subsystem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KL3101X1-BA1\u003c\/strong\u003e incorporates galvanic channel-to-channel isolation barriers between field terminal connections and internal bus circuits. By isolating individual signal pathways, the module suppresses common-mode ground loops and protects backplane electronics from field-side electrical surges. This isolation architecture maintains signal measurement integrity across 4-20 mA HART loop protocol instruments connected to DeltaV CHARM terminal carriers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the dual supply power requirements for the KL3101X1-BA1 module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires 6.3 VDC at 32 mA for internal logic processing circuits and 24 VDC at 25 mA to power the field loop excitation circuit.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical mounting executed for the KL3101X1-BA1 Electronic CHARM?\u003c\/p\u003e\n\u003cp\u003eA: The module latches directly into dedicated CHARM terminal blocks installed on DeltaV Electronic Marshalling carrier baseplates.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that backplane power is de-energized or ensure the surrounding environment is verified non-hazardous before inserting the CHARM module.\u003c\/li\u003e\n\u003cli\u003eInspect terminal base guiding keys and module contacts on the \u003cstrong\u003eKL3101X1-BA1\u003c\/strong\u003e for physical alignment prior to seating.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing over the designated CHARM terminal slot and push firmly until the mechanical retention latch engages.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring to the CHARM terminal base using shielded twisted-pair cabling for analog signal pathways.\u003c\/li\u003e\n\u003cli\u003eTerminate overall cable shields at a single chassis ground bar to ensure continuous electromagnetic noise suppression.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45353338044531,"sku":"KL3101X1-BA1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/KL3101X1-BA1_1200x1200_66dc8f26-ad41-4a3b-a02f-7aad8f205939.jpg?v=1786599385","url":"https:\/\/www.dcssupplier.com\/products\/emerson-kl3101x1-ba1-deltav-electronic-charm-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}