{"product_id":"emerson-mtl-8202-ho-is-analog-output-module","title":"Emerson MTL 8202-HO-IS Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMTL 8202-HO-IS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, intrinsically safe (IS)\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for hazardous area process control. It delivers high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals primarily used to drive I\/P (current-to-pressure) converters, control valves, and positioners.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8202-HO-IS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Single-ended output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA (for I\/P converters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntrinsically Safe field circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHART® pass-through; Variable and status reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4-20 mA mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 ms (typical), 80 ms (maximum)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~1 second per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Key Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e42 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e265 g (Net); 1.3 kg (Shipping)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen-circuit field wiring detection; Drive on \"Fail-safe\" (Upscale\/Downscale\/Last value)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel status (Active\/Inactive), HART reporting (Enable\/Disable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features \u0026amp; Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density IS Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides 8 channels of intrinsically safe outputs in a single 42mm module, significantly reducing cabinet space and barrier requirements in hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent HART Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe HART pass-through capability allows maintenance teams to perform remote diagnostics, range calibration, and status reporting of field positioners without visiting the site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Fail-Safe Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a communication loss, the module can be programmed to drive outputs to a predefined safety state (Upscale, Downscale, or Hold Last Value), preventing hazardous process excursions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Command Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a typical Railbus-to-output response of 20 ms, it provides the low-latency control required for high-performance process loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in open-circuit detection immediately alerts the control system if field wiring is compromised, allowing for proactive maintenance and reducing system downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eError-Proof Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe A4 mechanical keying ensures that only the correct module type can be inserted into the slot, protecting the system from incorrect voltage levels or signal types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44938841686131,"sku":"MTL 8202-HO-IS","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-08_16-17-47_71f4eef1-5feb-4bcf-ab15-55c6e49438be.png?v=1778230145","url":"https:\/\/www.dcssupplier.com\/products\/emerson-mtl-8202-ho-is-analog-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}