{"product_id":"emerson-pr6424-01-cs-con021-16mm-eddy-current-sensor","title":"Emerson PR6424\/01 CS CON021 16mm Eddy Current Sensor","description":"\u003cp\u003eConfigured for high-precision vibration and displacement measurement in rotating machinery platforms, the \u003cstrong\u003eEmerson PR6424\/01 CS CON021\u003c\/strong\u003e (\u003cstrong\u003ePR6424\u003c\/strong\u003e 16mm Eddy Current Sensor) provides direct physical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (PR6424)\u003c\/strong\u003e: High-resolution eddy-current displacement and vibration sensing probe series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix (\/01 CS CON021)\u003c\/strong\u003e: Designates the 16 mm sensor head geometry, integrated matching cable assembly, and matched CON021 signal converter interface configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6424\/01 CS CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 x 18 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +180 deg C (Standard probe operational range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven via CON021 signal converter execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e16 mm Eddy Current Vibration\/Displacement Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Output\u003c\/td\u003e\n\u003ctd\u003eAnalog displacement and vibration signal via CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO, DCS platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eConditioned signals generated via the CON021 signal converter module integrate into host automation architectures via analog outputs or 4-20 mA HART loop protocol interfaces. Channel-to-channel isolation safeguards the measurement loop against common-mode noise interference and ground potential differences across field instrumentation connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical parameter measurements does the PR6424\/01 CS CON021 deliver? A: The sensor provides non-contact dynamic vibration, relative displacement, and shaft position measurements using eddy current excitation.\u003c\/p\u003e\n\u003cp\u003eQ: Is the PR6424\/01 CS CON021 compatible with standard Emerson monitoring architectures? A: Yes, the sensor configuration integrates directly into Emerson EPRO monitoring systems and DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure a minimum of 5 full threads of engagement when screwing the sensor housing into the tapped machine bracket or casing port.\u003c\/li\u003e\n\u003cli\u003eRoute probe cabling through grounded metal conduit, isolated from high-voltage AC lines and variable frequency drive (VFD) output wiring.\u003c\/li\u003e\n\u003cli\u003eVerify that signal cable shielding is grounded at a single termination point (typically at the cabinet barrier or monitor rack terminal) to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eUse a feeler gauge or monitor the initial DC gap voltage output at the CON021 converter terminals to establish correct mid-scale physical clearance prior to operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45380817420403,"sku":"PR6424\/01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/PR9376-010-011_3.png?v=1787278951","url":"https:\/\/www.dcssupplier.com\/products\/emerson-pr6424-01-cs-con021-16mm-eddy-current-sensor","provider":"DcsSupplier Limited","version":"1.0","type":"link"}