{"product_id":"emerson-se3007-deltav-sx-controller","title":"Emerson SE3007 DeltaV SX Controller","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson SE3007\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSE3007\u003c\/strong\u003e SX Controller, operates as a dedicated hardware component for executing real-time distributed process control algorithms within DeltaV digital automation networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSE3007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV S-series controller footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied by System Power Supply through Local Carrier Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Redundancy\u003c\/td\u003e\n\u003ctd\u003eDual redundant network ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRedundant or simplex controller carrier slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Loop Execution\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Pass-Through\u003c\/strong\u003e: Decodes variable data from connected 4-20 mA HART smart field instruments, linking process diagnostics directly with the main logic task execution loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus Connectivity\u003c\/strong\u003e: Functions as the central communications link for managing digital signals originating from FOUNDATION Fieldbus and Profibus PA segment couplers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Control\u003c\/strong\u003e: Prevents high-frequency electrical disturbances from crossing from the external network interfaces into the internal control processing logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Switchover Latency\u003c\/strong\u003e: Supports 1-to-1 active-standby redundancy configuration, performing dynamic synchronization to execute bumpless transfer within 100 milliseconds upon diagnostic fault detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SE3007 controller support live insertion and removal (hot-swap) under active power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The SE3007 is hot-swappable when configured on a redundant carrier platform, allowing a single faulted unit to be removed and replaced without disrupting active control loop execution.\u003c\/p\u003e\n\u003cp\u003eQ: How is the physical control network redundancy configured on the SE3007 module?\u003c\/p\u003e\n\u003cp\u003eA: The controller interface couples with the local carrier slot to provide dual independent network interfaces, facilitating seamless physical path redundancy across the primary and secondary DCS networks.\u003c\/p\u003e\n\u003cp\u003eQ: What action occurs if the SE3007 experiences a complete processor watchdog timeout?\u003c\/p\u003e\n\u003cp\u003eA: Upon a watchdog timeout or total CPU execution failure, the controller drops its active signal, triggering an immediate switchover to the redundant backup controller on the carrier within 100 milliseconds.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Carrier Alignment\u003c\/strong\u003e: Align the rear terminal guides of the SE3007 with the designated slot on the active DeltaV carrier. Press the controller firmly into the carrier until the mechanical locking latch clicks into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding and Noise Shielding\u003c\/strong\u003e: Ensure the carrier mounting DIN rail is connected to the plant instrument ground busbar with a low-impedance copper strap of at least 4.0 mm squared cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Cooling Clearances\u003c\/strong\u003e: Mount the carrier assembly in a vertical orientation. Maintain a minimum of 100 mm vertical clearance above and below the controller module to permit free-air convection and keep temperatures below the 70 deg C threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45238989488243,"sku":"SE3007","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-06_15-10-43_2812f283-80a9-4949-b38e-115481f4fad5.png?v=1784100178","url":"https:\/\/www.dcssupplier.com\/products\/emerson-se3007-deltav-sx-controller","provider":"DcsSupplier Limited","version":"1.0","type":"link"}