{"product_id":"emerson-se5009-deltav-power-supply","title":"Emerson SE5009 DeltaV Power Supply","description":"\u003cp\u003eConfigured for stable DC power distribution within DeltaV M-series system platforms, the \u003cstrong\u003eEmerson SE5009\u003c\/strong\u003e (\u003cstrong\u003eSE5009\u003c\/strong\u003e System Power Supply) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSE5009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.72 kg (1.58 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV power supply footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated overcurrent and short-circuit monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV M-series power carrier slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Power Stabilization\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Compatibility\u003c\/strong\u003e: Incorporates high-attenuation electrical filtering to prevent high-frequency noise from corrupting super-imposed HART digital data on the analog loop supply lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e: Establishes continuous galvanic isolation barriers between the input supply circuits and the internal system backplane to block common-mode voltage transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Regulation Loop\u003c\/strong\u003e: Utilizes active voltage clamping feedback loops to supply stable, low-noise voltage rails to adjacent controller modules despite input line fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Feed Matching\u003c\/strong\u003e: Maintains continuous load balancing when deployed in multi-module redundant carrier architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SE5009 system power supply allow live replacement (hot-swap) during operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When installed on a redundant system power carrier alongside a secondary power supply module, the SE5009 can be hot-swapped under active power without interrupting control system execution.\u003c\/p\u003e\n\u003cp\u003eQ: Can the internal power protection components of the SE5009 be replaced on site?\u003c\/p\u003e\n\u003cp\u003eA: No. The SE5009 is built with sealed internal thermal and overcurrent protection fuses that are non-replaceable. A tripped internal fuse requires replacing the complete module assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What is the nominal input requirement to power the SE5009? A: The SE5009 requires a 24 VDC nominal power source supplied via the carrier backplane termination blocks.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion and Latching\u003c\/strong\u003e: Slide the SE5009 straight into the assigned slot on the power carrier. Press firmly until the mechanical locking latch clicks into place, confirming a complete electrical connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Grounding Requirements\u003c\/strong\u003e: Ensure the mounting DIN rail is connected to the plant instrument ground bus with a copper wire of at least 4.0 mm squared cross-section to optimize electrical noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Venting and Thermal Clearances\u003c\/strong\u003e: Mount the power supply carrier assembly horizontally. Provide a minimum of 100 mm vertical clearance above and below the modules to permit passive convection cooling and keep temperatures below 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45238989914227,"sku":"SE5009","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-15_15-22-15_bc736f49-b42d-481b-8a54-a44ddf0eef60.png?v=1784100181","url":"https:\/\/www.dcssupplier.com\/products\/emerson-se5009-deltav-power-supply","provider":"DcsSupplier Limited","version":"1.0","type":"link"}