{"product_id":"emerson-ve4017-fieldbus-h1-card","title":"Emerson VE4017 Fieldbus H1 Card","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson VE4017\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE4017\u003c\/strong\u003e Fieldbus H1 Card, operates as a dedicated hardware component for interfacing FOUNDATION Fieldbus H1 segments within Emerson DeltaV Distributed Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4017 (Series 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (Net)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard M-series controller carrier slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 320 mA (typical drawn from backplane carrier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Loop Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-20 mA HART loop protocol compatibility alongside digital trunk transmission enables hybrid instrument integration across field network nodes.\u003c\/li\u003e\n\u003cli\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity ensures deterministic real-time communication, supporting multi-drop network execution across individual port structures.\u003c\/li\u003e\n\u003cli\u003eChannel-to-channel isolation safeguards sensitive internal data pathways by mitigating electrical transients and ground differential potentials.\u003c\/li\u003e\n\u003cli\u003eCold junction compensation (CJC) parameters are maintained via system-level compensation models to ensure measurement stability on neighboring analog loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum physical device capacity per H1 port on this card?\u003c\/p\u003e\n\u003cp\u003eA: Each of the two ports can physically address up to 16 multi-drop devices, for a total of 32 devices per card. However, actual design limits depend on segment power supply capability, cable length, and overall loop execution latency requirements.\u003c\/p\u003e\n\u003cp\u003eQ: How does the card handle power distribution to the H1 field segments?\u003c\/p\u003e\n\u003cp\u003eA: The VE4017 interface card does not supply power directly to the H1 trunk. External, dedicated FOUNDATION Fieldbus power supplies and impedance matchers (conditioners) must be integrated into the segment wiring topology.\u003c\/p\u003e\n\u003cp\u003eQ: Is a redundant terminal block required to achieve 1:1 hardware redundancy?\u003c\/p\u003e\n\u003cp\u003eA: Yes. To implement a fully redundant H1 segment, a redundant terminal block must be combined with two active VE4017 interface modules. This allows the secondary card to instantly monitor and take over communication without dropping fieldbus packets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the carrier slot is clean and free of particulate debris prior to seating the VE4017 module to ensure reliable backplane connector engagement.\u003c\/li\u003e\n\u003cli\u003eSecure the module locking mechanisms fully to withstand industrial vibration profiles common in continuous process control environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper shielding and grounding practices on the fieldbus trunk cable to prevent noise coupling across the IEC 61158-2 physical layer.\u003c\/li\u003e\n\u003cli\u003eCheck external power supplies and bulk power isolators before energizing the H1 segment to prevent overvoltage conditions on the communication ports.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45267203522675,"sku":"VE4017","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-11_10-26-25_aafded66-7779-4ef4-a23c-7f54968ef3bb.png?v=1784612767","url":"https:\/\/www.dcssupplier.com\/products\/emerson-ve4017-fieldbus-h1-card","provider":"DcsSupplier Limited","version":"1.0","type":"link"}