{"product_id":"epro-con021-915-040-signal-converters","title":"EPRO CON021\/915-040 Signal Converters","description":"\u003cp\u003eThe \u003cstrong\u003eEPRO CON021\/915-040\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021\/915-040\u003c\/strong\u003e Signal Converter, operates as a dedicated hardware component for eddy current signal conditioning within MMS 6000 and IMR 6000 machinery monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/915-040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (120 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact rack module casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C (-22 deg F to +212 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via input supply -21 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eShaft displacement, position, eccentricity, and speed\/key signal conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probes\u003c\/td\u003e\n\u003ctd\u003ePR6422, PR6423, PR6424, PR6425, PR6426, PR6453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (Standard range with PR6425)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003eLess than 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e-23 VDC to -32 VDC (for -4 VDC to -20 VDC output) \/ -21 VDC to -32 VDC (for -2 VDC to -18 VDC output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eStandardized configurable analog signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock\u003c\/td\u003e\n\u003ctd\u003e5g at 60 Hz at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eLMgSi 0.5 F22 aluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-based, hot-swappable (MMS 6000 \/ IMR 6000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eSelf-locking LEMO plug or screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation and Eddy-Current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/915-040 converts high-frequency RF carrier signals from connected PR-series eddy current proximity probes into standardized analog DC output signals. Gap voltage validation targeting mid-scale negative DC targets ensures precise probe scaling across a 4.0 mm nominal measuring range with a linearity error within 1.5%. High dynamic frequency bandwidth from 0 Hz to 20000 Hz with a fast rise time under 15 us eliminates phase lag, preserving signal accuracy for dynamic shaft displacement, axial position, and speed\/keypulse processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021\/915-040 module be hot-swapped during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live hot-swappable insertion and removal in MMS 6000 and IMR 6000 rack enclosures without interrupting adjacent monitoring channels.\u003c\/p\u003e\n\u003cp\u003eQ: How is the linear measurement range verified during field installation?\u003c\/p\u003e\n\u003cp\u003eA: Verification is performed by adjusting probe mechanical gap clearance until the DC voltage output reaches the mid-scale bias voltage, establishing linear calibration over the 4.0 mm span.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the converter module firmly into the designated MMS 6000 or IMR 6000 rack slot to ensure proper backplane connector engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure continuous cable shielding from the non-contacting probe extension cable to the rack frame, grounding the shield at the rack end to prevent stray RF noise.\u003c\/li\u003e\n\u003cli\u003eVerify negative DC power supply levels (-21 VDC to -32 VDC) prior to powering field signal circuits.\u003c\/li\u003e\n\u003cli\u003eSeparate sensor signal lines from high-voltage AC electrical lines to avoid capacitive noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45491484131443,"sku":"CON021\/915-040","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CON021_PR6423002-001-CN_2_9667e0cb-e95b-4de1-9539-3fadc2740e59.jpg?v=1789357362","url":"https:\/\/www.dcssupplier.com\/products\/epro-con021-915-040-signal-converters","provider":"DcsSupplier Limited","version":"1.0","type":"link"}