{"product_id":"epro-pr6423-097-110-eddy-current-proximity-sensors","title":"EPRO PR6423\/097-110 Eddy Current Proximity Sensors","description":"\u003cp\u003eConfigured for shaft position, axial displacement, and dynamic relative vibration processing in industrial machinery protection platforms, the \u003cstrong\u003eEPRO PR6423\/097-110\u003c\/strong\u003e (\u003cstrong\u003ePR6423\u003c\/strong\u003e Eddy current sensor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe PR6423 non-contact displacement sensor platform uses structured order suffixes to designate thread sizes, body configurations, and cable configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePR6423\u003c\/strong\u003e: Base 8 mm tip diameter eddy current transducer series designed for contactless gap and vibration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/097-110\u003c\/strong\u003e: Specific hardware options designating metric\/imperial mounting threads, case construction features, armored or unarmored cable options, and cable length terminations for matching CON series signal conditioners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/097-110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20 cm x 20 cm x 15 cm (packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +180 deg C (sensor head assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via connected driver \/ signal conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Measuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (0.08 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8.0 V\/mm (203.2 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEPRO PR6423\/097-110\u003c\/strong\u003e functions via high-frequency eddy-current probe scaling to measure non-contact static distance and high-speed dynamic shaft motion against ferromagnetic target surfaces. Electromagnetic energy radiated from the 8 mm tip induces eddy currents in the target material, yielding a linear output voltage proportional to physical gap changes.\u003c\/p\u003e\n\u003cp\u003eDuring field configuration, gap voltage validation targets a nominal -10 VDC baseline at the center of the calibrated 2.0 mm linear range. Proper physical spacing and matching driver impedance provide critical cross-talk suppression between orthogonal x-y probe pairs mounted in turbo-machinery bearing housings, preventing mutual inductive coupling from affecting rotor dynamics monitoring accuracy.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the physical mounting gap set for the PR6423\/097-110 sensor during installation?\u003c\/p\u003e\n\u003cp\u003eA: The probe body is threaded toward the shaft until the static output voltage from the connected signal conditioner reaches the nominal center-scale value, typically -10 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions should be taken regarding the extension cable connections?\u003c\/p\u003e\n\u003cp\u003eA: Interconnecting connectors between the PR6423 sensor cable and the extension cable must be insulated from metallic conduit and machine housing using insulating sleeves or heat-shrink tubing to prevent unwanted ground contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the sensor tip perpendicular to the observed shaft target surface using threaded mounting ports or rigid brackets.\u003c\/li\u003e\n\u003cli\u003eMonitor the driver output voltage while adjusting thread engagement to achieve the target gap voltage (nominally -10 VDC).\u003c\/li\u003e\n\u003cli\u003eSecure the probe using jam nuts tightened to specified torque ratings to avoid mechanical drift under operational vibration.\u003c\/li\u003e\n\u003cli\u003eRoute extension cables in dedicated grounded flexible conduit, keeping signal paths clear of high-voltage supply lines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":48939936776307,"sku":"PR6423\/097-110","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CON021_PR6424002-010_1_9dadedfb-c623-40fe-901c-3211878bb00e.jpg?v=1790131624","url":"https:\/\/www.dcssupplier.com\/products\/epro-pr6423-097-110-eddy-current-proximity-sensors","provider":"DcsSupplier Limited","version":"1.0","type":"link"}