{"product_id":"epro-pr6424-010-131-contactless-sensor","title":"EPRO PR6424\/010-131 Contactless Sensor","description":"\u003cp\u003eConfigured for radial and axial shaft dynamic displacement measurement in turbomachinery protection systems, the \u003cstrong\u003eEPRO PR6424\/010-131\u003c\/strong\u003e (\u003cstrong\u003ePR6424\u003c\/strong\u003e 16mm Eddy Current Sensor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6424\/010-131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany (DE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor element (powered via external signal conditioner \/ transmitter unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- \u0026lt;0.079 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e+\/- \u0026lt;0.039 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integrity\u003c\/h3\u003e\n\u003cp\u003eThe PR6424 16mm non-contact sensor operates on electro-magnetic eddy-current probe scaling principles, converting target shaft proximity into calibrated high-frequency magnetic field degradation. Tailored for heavy rotor dynamics monitoring, the transducer tip maintains precise gap voltage validation across its calibrated linear range (-2.0 to 2.0 mm). Nominal gap voltage target setting (typically calibrated near -10 VDC at mid-scale depending on matching signal conditioner calibration) prevents signal clipping during high-amplitude transient dynamic excursions. The high physical symmetry of the coil construction ensures cross-talk suppression when installed in orthogonal pair configurations for dual-plane shaft vibration analysis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the recommended target gap setting procedure during installation?\u003c\/p\u003e\n\u003cp\u003eA: Mechanical target alignment requires setting the probe to the electrical midpoint within the linear range (-2.0 to 2.0 mm). Verify the raw bias gap voltage output at the driver\/transmitter unit against the specific calibration curve (typically targeting -10 VDC static bias) using a calibrated digital multimeter before securing locknuts.\u003c\/p\u003e\n\u003cp\u003eQ: How does cable extension routing affect measurement accuracy and signal integrity?\u003c\/p\u003e\n\u003cp\u003eA: Total electrical length matching between the sensor, extension cable, and transmitter unit is critical for accurate oscillator frequency response and eddy-current probe scaling. Deviations in overall cable length or improper shielding connection will shift the calibrated linear range and degrade signal-to-noise performance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Surface Preparation:\u003c\/strong\u003e Ensure the target shaft area is free from deep mechanical scratches, magnetic runoff, and surface rust. Shaft runout must be verified with a dial indicator prior to final sensor mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Torque \u0026amp; Engagement:\u003c\/strong\u003e Mount the sensor rigid bracket to eliminate resonance interference. Thread engagement into probe holders or glands must be secured without over-torquing to prevent mechanical stress on the 16 mm sensing tip assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief and Shielding:\u003c\/strong\u003e Route high-frequency extension cables through dedicated grounded conduit, maintaining distance from high-voltage motor supply lines. Ground cable shields strictly at the monitor panel end to prevent ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":48384387907699,"sku":"PR6424\/010-131","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CON021_PR6424002-010_1_9cf36efa-d19b-40ee-a149-37556c53c221.jpg?v=1789958276","url":"https:\/\/www.dcssupplier.com\/products\/epro-pr6424-010-131-contactless-sensor","provider":"DcsSupplier Limited","version":"1.0","type":"link"}