{"product_id":"epro-pr9268-300-000-electrodynamic-velocity-sensor","title":"EPRO PR9268\/300-000 Electrodynamic Velocity Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eEPRO PR9268\/300-000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePR9268\u003c\/strong\u003e Electrodynamic Velocity Sensor, operates as a dedicated hardware component for precise vibration velocity measurement within critical machinery infrastructure. It converts mechanical casing or structural vibrations directly into standardized loop currents natively at the device tier to communicate machinery health metrics parallel to master control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR9268\/300-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.1 cm x 15.9 cm x 10.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectrodynamic Velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 100 m\/s (0.3 to 328 ft\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Profile\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC loop current proportional to vibration velocity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e4 to 1000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e28.5 mV\/mm\/s (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C (-40 deg F to +176 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP67 certified isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Monitoring \u0026amp; TSI Signal Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling and Coil Electrodynamics:\u003c\/strong\u003e The sensor employs an internal electrodynamic coil-and-magnet arrangement that measures absolute casing vibration relative to free space. As the mechanical housing oscillates within the 4 to 1000 Hz frequency range, the self-generating core induces a voltage trace that bypasses external eddy-current probe scaling constraints to drive the internal transmitter circuitry directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation and Calibration Linearization:\u003c\/strong\u003e Unlike proximity systems requiring constant gap voltage validation, the electrodynamic element relies on its internal mechanical suspension remaining clear of internal physical travel stops. The internal signal conditioning electronics convert the induced dynamic millivolt signals into a highly linearized 4-20 mA output curve covering the 0.1 to 100 m\/s tracking window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Suppression and Inductive Shielding:\u003c\/strong\u003e The module is enclosed in a sealed, heavy-walled case that shields the internal coil array from ambient magnetic fields generated by nearby industrial motors. This inductive isolation ensures high cross-talk suppression, ensuring that neighboring sensor runs inside shared machinery conduits do not induce noise loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What distinct loop behavior will manifest if the 24 V DC power supply drops below the minimal operating threshold?\u003c\/p\u003e\n\u003cp\u003eA: If the primary 24 V DC loop voltage dips below the device operating limits, the internal transmitter circuitry will lose regulation, dropping the output loop current below the standard 4.0 mA baseline to alert the supervisory PLC or DCS of an input loop fault.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 0.3 kg velocity sensor be hard-mounted directly onto a machine casing that operates consistently at +120 deg C?\u003c\/p\u003e\n\u003cp\u003eA: No. The PR9268\/300-000 features an operating temperature cap of +80 deg C. Exceeding this boundary risk permanently degrading the internal signal conditioning electronics, shifting coil calibration parameters, and invalidating the certified IP67 environmental isolation seals.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45130032414835,"sku":"PR9268\/300-000","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/87a2d25a21e917f5d1a82f9a1ca690b16_173b329a-92ed-483b-8b54-8112c8ea5e41.png?v=1782292464","url":"https:\/\/www.dcssupplier.com\/products\/epro-pr9268-300-000-electrodynamic-velocity-sensor","provider":"DcsSupplier Limited","version":"1.0","type":"link"}