{"product_id":"foxboro-sy-6014604a-dual-channel-serial-communication-module","title":"Foxboro SY-6014604A Dual-channel Serial Communication Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro SY-6014604A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized dual-channel serial communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro SCD6000 and SCD5200 SCADA\/RTU platforms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt provides a secure and flexible communication bridge between the RTU’s internal database and external field devices.\u003c\/p\u003e\n\u003ch2\u003e1. Module Functionality\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Independent Serial Channels\u003c\/strong\u003e\u003cbr\u003eEach channel operates separately, allowing simultaneous communication with different devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Electrical Standards\u003c\/strong\u003e\u003cbr\u003eEach port can be individually configured for:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-485 (2-wire or 4-wire)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-422\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Protocol Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Master \/ Slave)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(RTU \/ ASCII)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 60870-5-101\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Level Isolation\u003c\/strong\u003e\u003cbr\u003e1 kV\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field ports and RTU logic protects the system from noise, surges, and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e2. Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Types\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485 (2-wire or 4-wire), RS-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e2 independent serial channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1000 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Baud Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 115.2 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eDB9 or plug-in screw terminals (card-file dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e3. Where It Fits in Your System\u003c\/h2\u003e\n\u003cp\u003eIn a typical Foxboro RTU stack, the module hierarchy looks like this:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSY-1025120E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe Brain\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003e(main processor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSY-6014604A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe Translator\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003e(serial communications to field devices)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSY-0301069C \/ SY-0303440E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe Hands\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003e(digital and analog signal I\/O)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTogether, these modules form a complete\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield-to-SCADA communication chain\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":44265579118707,"sku":"SY-6014604A","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/chk_1_e29f1a18-b861-4362-bf8a-4cb569b20d3d.jpg?v=1770082191","url":"https:\/\/www.dcssupplier.com\/products\/foxboro-sy-6014604a-dual-channel-serial-communication-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}