{"product_id":"ge-336a4937rdg004-pac-power-wire-assembly","title":"GE 336A4937RDG004 PAC Power Wire Assembly","description":"\u003cp\u003eConfigured for power distribution and signal transmission in GE Mark Ve Gas Turbine Control Systems, the \u003cstrong\u003eGE 336A4937RDG004\u003c\/strong\u003e (\u003cstrong\u003e336A4937RDG004\u003c\/strong\u003e PAC Power Wire Assembly) provides direct physical\/electrical execution. The wire sub-assembly routes localized control loop current and logic power lines natively at the hardware tier to interconnect internal power backplanes and card racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e336A4937RDG004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V System Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg net physical mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 inches continuous conductor length path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C absolute operational limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive conductor loop distribution line drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Geometry\u003c\/td\u003e\n\u003ctd\u003e20 AWG multi-strand core configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Type\u003c\/td\u003e\n\u003ctd\u003ePAC Power-JPDL thermal dielectric jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Wiring Harnesses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drives Backplane Infrastructure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Control Core Distribution\u003c\/strong\u003e The 4-inch assembly establishes a dedicated point-to-point connection within the controller rack framework to handle low-voltage power distribution. This physical harness layout enables tight module grouping and supports high I\/O density scaling by routing core power tracks around confined chassis paths without causing mechanical binding or limiting airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP and Deterministic Logic Coexistence\u003c\/strong\u003e The heavy-gauge 20 AWG conductor geometry is engineered to reduce internal line impedance and minimize high-frequency noise emissions from the switching bus. This reduction in electromagnetic cross-talk allows the power distribution assembly to run close to communication links connected to Profinet \/ EtherNet\/IP deterministic networks without causing data packet corruption or signal reflection anomalies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the PAC Power-JPDL insulation layer perform under sustained heat exposure inside turbine enclosures?\u003c\/p\u003e\n\u003cp\u003eA: The JPDL insulation consists of a high-temperature dielectric compound rated to withstand a continuous operational envelope from -40 to +70 deg C. The polymer jacket resists chemical breaking, embrittlement, and thermal outgassing when mounted inside unventilated control cabinets exposed to ambient turbine deck radiant heat.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 20 AWG wire assembly be fieldsman-altered or spliced to increase the 4-inch length?\u003c\/p\u003e\n\u003cp\u003eA: No, modification of the pre-fabricated 336A4937RDG004 wire assembly is not permitted. The harness features factory-crimped, low-resistance termination points calibrated to match standard Mark V power board receptacles; field splices degrade signal parameters and compromise structural continuity under vibration.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45109756330099,"sku":"336A4937RDG004","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screensho1t_2026-05-08_18-01-35_8e0d1706-cbe5-4033-b4e9-e644eef00eb9.png?v=1781674764","url":"https:\/\/www.dcssupplier.com\/products\/ge-336a4937rdg004-pac-power-wire-assembly","provider":"DcsSupplier Limited","version":"1.0","type":"link"}