{"product_id":"ge-a14b-0067-b002-01-power-supply-unit","title":"GE A14B-0067-B002-01 Power Supply Unit","description":"\u003cp\u003eConfigured for DC logic rail generation and system bus excitation in System 3T\/M basic unit chassis, the \u003cstrong\u003eGE A14B-0067-B002-01\u003c\/strong\u003e ( \u003cstrong\u003eA14B-0067-B002\u003c\/strong\u003e Power Supply Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration \/ Application Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA14B-0067-B002\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eStandard Power Supply 3 Control for System 3T\/M CNC Main Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA14B-0067-B002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ FANUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.41 lbs (2.00 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Controller Chassis Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Load Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eSystem 3T\/M Basic Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubsystem Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply 3 Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe power supply unit maintains regulated DC output stability across the local backplane bus communication velocity architecture during dynamic load shifts. Stable line regulation prevents logic voltage dips that could compromise high-speed processing and deterministic communication across main CPU and axis control cards. Voltage supervision circuitry ensures system logic remains held in reset until primary power rails stabilize, protecting firmware flash compatibility execution routines during initial power-up sequences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What precautions are required when replacing the A14B-0067-B002-01 in a System 3T\/M rack?\u003c\/p\u003e\n\u003cp\u003eA: Ensure incoming AC lines are fully isolated. The unit must not be inserted or removed while power is applied to prevent edge connector arc damage and logic latch-up states.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit feature internal output monitoring for backplane bus faults?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The power supply incorporates overvoltage and overcurrent sensing that pulls the system power-good line low to halt CNC operations if secondary voltage rails drift outside tolerance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate and lock out incoming mains power before opening the CNC cabinet or accessing the basic unit chassis.\u003c\/li\u003e\n\u003cli\u003eAlign the board edges with the chassis guide slots to prevent pin misalignment on the rear backplane interface.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly into the rack connector until fully seated, then secure all retaining screws to confirm grounding continuity.\u003c\/li\u003e\n\u003cli\u003eVerify all wiring, terminal connections, and external cable shields are clean, tight, and grounded according to industrial noise suppression standards.\u003c\/li\u003e\n\u003cli\u003eApply power and verify the power supply status indicators light up correctly before enabling axis drives.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45455691087987,"sku":"A14B-0067-B002-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A14B-0061-B001_Cocoai_e73f84b5-d2da-4f0b-bdd2-74d54ef9e597.jpg?v=1788753109","url":"https:\/\/www.dcssupplier.com\/products\/ge-a14b-0067-b002-01-power-supply-unit","provider":"DcsSupplier Limited","version":"1.0","type":"link"}