{"product_id":"ge-cqpm3d200b2p-a-operator-interfaces","title":"GE CQPM3D200B2P-A Operator Interfaces","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc CQPM3D200B2P-A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCQPM3D200\u003c\/strong\u003e QuickPanel Jr. Operator Interface, operates as a dedicated hardware component for human-machine visualization and control input execution within industrial control systems. It provides visual data output via a 5.7-inch monochrome LCD display with a 320 x 240 pixel resolution and accepts operator commands via an integrated touch screen surface. The unit communicates directly with programmable controllers to process status telemetry and operational commands.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCQPM3D200B2P-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Total Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Assembled in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg (1.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170.43 mm x 137.92 mm x 87.3 mm (6.71 in x 5.43 in x 3.437 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 deg C (32 to 104 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum (Typical 13 W, 20 W max rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eQuickPanel Jr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e5.7-inch Monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Acceptable range: 20 to 27 VDC \/ 20.4 to 27.6 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Voltage Withstand\u003c\/td\u003e\n\u003ctd\u003e1000 VAC at 10 mA for 1 minute between terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Immunity Duration\u003c\/td\u003e\n\u003ctd\u003e20 ms following power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C (-4 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc CQPM3D200B2P-A\u003c\/strong\u003e interface coordinates serial and network communication sweeps to match host PLC processing cycles. Preloaded firmware flash compatibility ensures real-time synchronicity when uploading system runtime projects developed via QuickDesigner Version 3.7. Internal system architecture executes rapid hardware diagnostics during start-up, maintaining deterministic input processing without introducing serial latency or buffer overruns to the underlying control loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the display if the operational temperature exceeds 40 deg C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Operating the unit in ambient conditions exceeding 40 deg C causes screen contrast and brightness to diminish.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum allowable mounting incline angle for the CQPM3D200B2P-A enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit must not be mounted at an incline greater than 30 degrees. If installed at an incline up to 30 degrees, ambient temperatures must be monitored to ensure they do not exceed 40 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the internal power supply handle brief voltage drops or power interruptions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit incorporates built-in power immunity capabilities that keep the unit functional for up to 20 ms following a power loss.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout Preparation\u003c\/strong\u003e: Cut the panel opening according to specified cutout dimensions. Ensure surrounding panel surfaces are clean, flat, and free of burrs to preserve NEMA Type 4X\/12 (IP65) sealing integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Insertion and Orientation\u003c\/strong\u003e: Mount the unit into the cabinet panel face. Ensure the operational incline does not exceed 30 degrees from the vertical plane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGasket Sealing \u0026amp; Clamp Securing\u003c\/strong\u003e: Insert the unit through the cutout with the sealing gasket fully engaged. Tighten panel mounting clamps evenly around the bezel frame to apply uniform compression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power Wiring\u003c\/strong\u003e: Connect a regulated 24 VDC power source (20.4 to 27.6 VDC) using stranded copper conductors. Verify correct wire polarity before energizing the terminal block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Grounding\u003c\/strong\u003e: Attach a dedicated ground wire from the chassis ground terminal directly to the enclosure star ground bus to minimize electrical noise susceptibility and static discharge risk.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45434639450227,"sku":"CQPM3D200B2P-A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QPI-3D200-E2P_3_6d3d6a5e-d098-4a31-ac38-c77dac8fa630.png?v=1788314234","url":"https:\/\/www.dcssupplier.com\/products\/ge-cqpm3d200b2p-a-operator-interfaces","provider":"DcsSupplier Limited","version":"1.0","type":"link"}