{"product_id":"ge-ds200tbqbg1a-input-termination-module","title":"GE DS200TBQBG1A Input Termination Module","description":"\u003cp\u003eConfigured for analog signal termination and pulse rate processing in Mark V turbine control systems, the \u003cstrong\u003eGE DS200TBQBG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200TBQBG1A\u003c\/strong\u003e) input termination module provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eMark V series printed circuit board hardware architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTBQB\u003c\/td\u003e\n\u003ctd\u003eInput and analog termination board functional circuit grouping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG1A\u003c\/td\u003e\n\u003ctd\u003eFirst major hardware revision designator for Mark V turbine platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQBG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eVerified Industrial Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard industrial component weight (platform dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V modular terminal board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on connected signal loop excitation and backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eAnalog signal termination, 4-20 mA loop scaling, and pulse rate input processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates high-speed backplane bus communication channels linked directly to the TCQA board assembly, supporting deterministic transmission of vibration, analog current, and voltage signals across Mark V core environments. Onboard jumper configurations (BJ1 through BJ15) allow physical scaling of pressure transducer and analog inputs between current and voltage modes. Firmware flash compatibility and hardware revision handshaking must be verified during system integration to ensure proper signal interpretation and alarm handling across redundant controller racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the board configuration jumpers be modified while the turbine system is running?\u003c\/p\u003e\n\u003cp\u003eA: No, all jumper position changes for current and voltage selection must be performed while the system is fully de-energized to prevent signal corruption and control faults.\u003c\/p\u003e\n\u003cp\u003eQ: How is signal troubleshooting performed given the absence of onboard diagnostic LEDs and test points?\u003c\/p\u003e\n\u003cp\u003eA: System-level diagnostics are executed through programmable read-only memory (PROM) tools accessible from the control panel, generating status reports for the entire drive configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure proper electrostatic discharge (ESD) wrist strap grounding prior to handling or mounting the termination module. Secure the board firmly onto designated structural standoffs within the control cabinet, and connect field wiring to the dual 77-terminal blocks while respecting proper shielding and torque limits. Verify all JGR, JHR, and JGS\/T connector seatings to ensure secure mechanical and electrical integration before restoring system power.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45267285901427,"sku":"DS200TBQBG1A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-14_10-50-59__1_290b5394-51b8-4975-a11f-daefd7a6d971.png?v=1784605763","url":"https:\/\/www.dcssupplier.com\/products\/ge-ds200tbqbg1a-input-termination-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}