{"product_id":"ge-ds200tccbg1b-common-extended-analog-io-board","title":"GE DS200TCCBG1B Common Extended Analog IO Board","description":"\u003cp\u003eConfigured for analog signal scaling and conditioning in Mark V turbine control system platforms, the \u003cstrong\u003eGE DS200TCCBG1B\u003c\/strong\u003e (\u003cstrong\u003eDS200TCCBG1B\u003c\/strong\u003e Common Extended Analog IO Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix \/ Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TCCBG1\u003c\/td\u003e\n\u003ctd\u003eBase parent printed circuit board version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TCCBG1B\u003c\/td\u003e\n\u003ctd\u003eB-rated functional product revision incorporating updated hardware layout and performance tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCCBG1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.5 cm x 19.0 cm x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 2PL TCPS board power distribution connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackplane bus communication velocity and firmware flash compatibility are maintained across the Mark V rack infrastructure to ensure deterministic analog processing.\u003c\/li\u003e\n\u003cli\u003eProfinet and EtherNet\/IP deterministic network integration relies on precise connector mapping, including the JHH and JII inputs, to prevent data latency or protocol misalignment.\u003c\/li\u003e\n\u003cli\u003eI\/O density scaling supports 4-20 mA and 0-1 mA input circuits, utilizing dedicated 50-pin connectors (JCC and JDD) alongside onboard microprocessors and PROM modules for signal conditioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is DS200TCCBG1B's input circuitry?\u003c\/p\u003e\n\u003cp\u003eA: DS200TCCBG1B has 4-20 mA input circuit. DS200TCCBG1B provides the circuitry for the 4-20 mA and 0-1 mA input signals. The signals are read from DS200TCCBG1B through the JHH connector.\u003c\/p\u003e\n\u003cp\u003eQ: What are the connectors on DS200TCCBG1B?\u003c\/p\u003e\n\u003cp\u003eA: DS200TCCBG1B has 8 connectors. DS200TCCBG1B has a 2PL, 3PL, JHH, JII, JMP, JKK, JTEST, and TCQPL connector. Connectors JKK, JTEST, and TCQPL on DS200TCCBG1B are typicaly not used on DS200TCCBG1B.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of DS200TCCBG1B?\u003c\/p\u003e\n\u003cp\u003eA: The primary function of DS200TCCBG1B is to provide scaling and conditioning for additional analog I\/O signals read for the TBCB terminal board mounted on the \u0026lt; R5 \u0026gt; core and the TCEB board in the \u0026lt; P1 \u0026gt; core.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure system power is completely isolated and locked out before removing or installing the printed circuit board.\u003c\/li\u003e\n\u003cli\u003eVerify default positions of jumpers JP1, JP2, and JP3 prior to commissioning, modifying only per specific configuration requirements outlined in system documentation.\u003c\/li\u003e\n\u003cli\u003eInspect connector pins and ensure all ribbon and power cables, such as the 2PL and 3PL connections, are securely locked to prevent intermittent signal loss under high-vibration turbine conditions.\u003c\/li\u003e\n\u003cli\u003eMaintain proper electrostatic discharge (ESD) precautions during handling to protect onboard microprocessors and memory modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45265346527347,"sku":"DS200TCCBG1B","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-09_15-59-35_95738ce5-77af-4b12-b3af-a3b4db76f5a1.png?v=1784596748","url":"https:\/\/www.dcssupplier.com\/products\/ge-ds200tccbg1b-common-extended-analog-io-board","provider":"DcsSupplier Limited","version":"1.0","type":"link"}