{"product_id":"ge-fanuc-2780051-2-quickpanel-hmi","title":"GE Fanuc 2780051-2 QuickPanel HMI","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc 2780051-2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2780051-2\u003c\/strong\u003e QuickPanel (HMI), operates as a dedicated hardware component for process data visualization and user command entry within GE Fanuc PLC and automation controller networks. It processes operator touch input across its resistive screen matrix to replace discrete push buttons, selector switches, and indicator lamps.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2780051-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eQuickPanel HMIs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eMonochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Size\u003c\/td\u003e\n\u003ctd\u003e6 inches diagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 240 pixels (QVGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eCCFL (replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Technology\u003c\/td\u003e\n\u003ctd\u003eResistive analog (4-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232, 1 x RS-422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Interfaces\u003c\/td\u003e\n\u003ctd\u003e1 x Parallel Printer Port, 1 x Programming Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Baud Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 115,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout Size\u003c\/td\u003e\n\u003ctd\u003e178 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Panel Thickness\u003c\/td\u003e\n\u003ctd\u003e1.5 to 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e210 mm x 152 mm x 56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.95 kg (2.09 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDrawn via 24 VDC external supply connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Deterministic Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe QuickPanel unit interfaces with controller architecture across serial communications links, maintaining low-latency scan rates up to 115,200 bps over RS-422\/485 multi-drop networks. High I\/O density scaling maps screen register tags directly to PLC memory locations, eliminating backplane communications overhead. Onboard firmware flash compatibility ensures synchronized screen display updates and real-time command transmission during active CPU scan cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are available on the 2780051-2 unit for connecting to external PLCs?\u003c\/p\u003e\n\u003cp\u003eA: The unit features one RS-232 serial port for point-to-point connections, one RS-422\/485 port for multi-drop networks, a dedicated programming port, and a parallel printer port.\u003c\/p\u003e\n\u003cp\u003eQ: Is the front bezel of the 2780051-2 rated for washdown or dusty environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, when mounted using the proper sealing gasket and retaining clips, the front panel achieves an IP65 protection rating against dust ingress and low-pressure water jets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCut out a 178 mm x 130 mm opening in the enclosure door, ensuring panel thickness is between 1.5 mm and 6 mm.\u003c\/li\u003e\n\u003cli\u003eInspect the rear sealing gasket around the front bezel perimeter to confirm it is free of damage or dirt.\u003c\/li\u003e\n\u003cli\u003eInsert the 2780051-2 unit into the panel cutout from the front side.\u003c\/li\u003e\n\u003cli\u003eAttach the mounting clips to the unit housing from inside the cabinet and tighten screws evenly to achieve a uniform IP65 seal against the panel face.\u003c\/li\u003e\n\u003cli\u003eTerminate the RS-232 or RS-422\/485 communication cables, connect the 24 VDC supply wiring, and ensure shield wires are grounded to the enclosure frame.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":66727584792691,"sku":"2780051-2","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2780051-2_Cocoai_a26b1355-2c50-4ac1-a783-604be0eeffa1.jpg?v=1790565861","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-2780051-2-quickpanel-hmi","provider":"DcsSupplier Limited","version":"1.0","type":"link"}