{"product_id":"ge-fanuc-8201-hi-is-analog-input-module","title":"GE Fanuc 8201-HI-IS Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc 8201-HI-IS\u003c\/strong\u003e serves as the primary \u003cstrong\u003e8201-HI-IS\u003c\/strong\u003e Analog Input Module utilized to execute process signal conditioning and HART variable pass-through in hazardous area loops across GE PAC8000 platforms. The 8-channel module connects 2-wire field transmitters located in intrinsically safe zones directly to the PAC8000 Railbus, executing 16-bit analog-to-digital signal conversion while streaming HART diagnostic and process data to higher-level automation controllers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8201-HI-IS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (Shipping Weight: 2.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eModule Width: 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eIn-built transmitter power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003eNominal: 4 to 20 mA, Full: 0.5 to 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution, accuracy +-20 uA at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Safety\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe (Ex i)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003ePAC8000 I\/O System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Channel-to-Channel HART Loops\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates intrinsically safe barrier circuitry, providing 60 VAC isolation between field input circuits and the internal Railbus backplane. An internal power supply delivers a minimum of 15 V at 20 mA to drive field 2-wire transmitters across each input channel. Integrated HART communication modems pass secondary dynamic variables and status flags over the 4-20 mA current loop directly to control network software without interrupting continuous analog process data conversion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 8201-HI-IS module report field wiring and sensor integrity faults?\u003c\/p\u003e\n\u003cp\u003eA: The module executes continuous line fault detection on current levels, generating an open-circuit alarm when input current drops below 0.5 mA and a short-circuit alarm when current exceeds 21.5 mA.\u003c\/p\u003e\n\u003cp\u003eQ: Is channel-to-channel isolation provided on the 8201-HI-IS module?\u003c\/p\u003e\n\u003cp\u003eA: No, the 8 single-ended input channels share a common internal signal ground within the module, though the entire channel bank maintains 60 VAC galvanic isolation from the Railbus backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module card edge with the designated carrier slot and push firmly until the locking tabs engage the carrier frame.\u003c\/li\u003e\n\u003cli\u003eLand 2-wire field transmitter conductors onto the corresponding intrinsically safe field terminal block assembly.\u003c\/li\u003e\n\u003cli\u003eSeparate intrinsically safe field cable runs from non-intrinsically safe power and control cables in panel wire trunks by a minimum distance of 50 mm.\u003c\/li\u003e\n\u003cli\u003eGround cable overall shield drains directly to the panel equipotential earth bar to minimize common-mode noise on the analog signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45371422474355,"sku":"8201-HI-IS","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/8201-HI-IS_1200x1200_e73c051c-c1f0-4078-8b29-302586568c40.jpg?v=1787044030","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-8201-hi-is-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}