{"product_id":"ge-fanuc-a03b-0807-c001-i-o-module-base-unit","title":"GE Fanuc A03B-0807-C001 I\/O Module Base Unit","description":"\u003cp\u003eConfigured for slot expansion and signal distribution in industrial control architectures, the \u003cstrong\u003eGE Fanuc A03B-0807-C001\u003c\/strong\u003e (\u003cstrong\u003eA03B-0807-C001\u003c\/strong\u003e I\/O Module Base Unit) provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Model Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSlot Capacity\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eVoltage Requirement\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA03B-0807-C001\u003c\/td\u003e\n\u003ctd\u003e10 Slots\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Direct Panel\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA03B-0807-Base\u003c\/td\u003e\n\u003ctd\u003e10 Slots\u003c\/td\u003e\n\u003ctd\u003eUnpopulated Substrate\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA03B-0807-C001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFactory Designated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.57 kg (1.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHorizontal mounting layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e10 slots (digital\/analog support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eDIN rail or direct panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eStandard industrial chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Network Operations\u003c\/h3\u003e\n\u003cp\u003eConfigured to interface with deterministic controller backplanes, the base unit leverages optimized internal signal routing traces to support high-speed data exchange across mounted I\/O modules. Backplane bus communication velocity and firmware flash compatibility remain synchronized with the system processor, ensuring deterministic polling rates and zero transmission collisions across all ten expansion slots.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can master CPU modules be installed directly into the A03B-0807-C001 base unit slots?\u003c\/p\u003e\n\u003cp\u003eA: No, this unit functions exclusively as an I\/O expansion base unit, and master CPU modules must be placed on the primary controller rack.\u003c\/p\u003e\n\u003cp\u003eQ: How is operating power distributed across the ten module slots?\u003c\/p\u003e\n\u003cp\u003eA: A nominal 24 V DC input power supply is wired directly to the baseplate terminals, which internally route and distribute power to all connected digital and analog I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the main power supply and controller rack are completely de-energized before mounting the base unit onto a DIN rail or direct panel surface. Verify proper horizontal alignment and clearance to maintain ambient operating temperatures below 55 deg C. Route all field I\/O wiring separately from high-voltage power lines and ensure solid chassis grounding to suppress electromagnetic interference.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":66868583530611,"sku":"A03B-0807-C001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A03B-0807-C001_Cocoai.jpg?v=1792050148","url":"https:\/\/www.dcssupplier.com\/products\/ge-fanuc-a03b-0807-c001-i-o-module-base-unit","provider":"DcsSupplier Limited","version":"1.0","type":"link"}